A new electrophysiological method for the diagnosis of extraforaminal stenosis at L5-s1

A retrospective study. To examine the effectiveness of using an electrodiagnostic technique as a new approach in the clinical diagnosis of extraforaminal stenosis at L5-S1. We introduced a new effective approach to the diagnosis of extraforaminal stenosis at the lumbosacral junction using the existi...

Full description

Saved in:
Bibliographic Details
Published inAsian spine journal Vol. 8; no. 2; pp. 145 - 149
Main Authors Iwasaki, Hiroshi, Yoshida, Munehito, Yamada, Hiroshi, Hashizume, Hiroshi, Minamide, Akihito, Nakagawa, Yukihiro, Kawai, Masaki, Tsutsui, Shunji
Format Journal Article
LanguageEnglish
Published Korea (South) Korean Society of Spine Surgery 01.04.2014
Korean Spine Society
대한척추외과학회
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A retrospective study. To examine the effectiveness of using an electrodiagnostic technique as a new approach in the clinical diagnosis of extraforaminal stenosis at L5-S1. We introduced a new effective approach to the diagnosis of extraforaminal stenosis at the lumbosacral junction using the existing electrophysiological evaluation technique. A consecutive series of 124 patients with fifth lumbar radiculopathy were enrolled, comprising a group of 74 patients with spinal canal stenosis and a second group of 50 patients with extraforaminal stenosis at L5-S1. The technique involved inserting a pair of needle electrodes into the foraminal exit zone of the fifth lumbar spinal nerves, which were used to provide electrical stimulation. The compound muscle action potentials from each of the tibialis anterior muscles were recorded. The distal motor latency (DML) of the potentials ranged from 11.2 to 24.6 milliseconds in patients with extraforaminal stenosis. In contrast, the DML in patients with spinal canal stenosis ranged from 10.0 to 17.2 milliseconds. After comparing the DML of each of the 2 groups and at the same time comparing the differences in DML between the affected and unaffected side of each patient, we concluded there were statistically significant differences (p<0.01) between the 2 groups. Using receiver operating characteristic curve analysis, the cutoff values were calculated to be 15.2 milliseconds and 1.1 milliseconds, respectively. This approach using a means of DML measurement enables us to identify and localize lesions, which offers an advantage in diagnosing extraforaminal stenosis at L5-S1.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1976-1902
1976-7846
DOI:10.4184/asj.2014.8.2.145