Immediate Impact of Artificial Tear Composition on Optical Aberrations: A Comparative Study of Lipid and Non-Lipid Hydroxypropyl Guar Formulations

Introduction To evaluate the immediate effects of two artificial tear formulations—mineral oil + hydroxypropyl guar (HP-Guar) and hyaluronic acid (HA) + HP-Guar—on ocular aberrations in healthy participants. Methods A randomized, participant-masked clinical trial was conducted on 98 right eyes of 98...

Full description

Saved in:
Bibliographic Details
Published inOphthalmology and therapy Vol. 14; no. 9; pp. 2165 - 2178
Main Authors Sánchez-González, José-María, Sánchez-González, María Carmen, De-Hita-Cantalejo, Concepción, Nascimento, Henrique, Martinez-Perez, Clara
Format Journal Article
LanguageEnglish
Published Cheshire Springer Healthcare 01.09.2025
Springer Nature B.V
Adis, Springer Healthcare
Subjects
Online AccessGet full text
ISSN2193-8245
2193-6528
DOI10.1007/s40123-025-01205-z

Cover

More Information
Summary:Introduction To evaluate the immediate effects of two artificial tear formulations—mineral oil + hydroxypropyl guar (HP-Guar) and hyaluronic acid (HA) + HP-Guar—on ocular aberrations in healthy participants. Methods A randomized, participant-masked clinical trial was conducted on 98 right eyes of 98 participants (mean age: 27.96 ± 10.00 years). Participants received a single instillation of either a lipid-based (mineral oil + HP-Guar) or non-lipid (HA + HP-Guar) artificial tear solution. Ocular aberrations were measured before and 10 min post-instillation using a wavefront aberrometer (i.Profilerplus ® , Carl Zeiss Meditec, Jena, Germany) at pupil diameters of 3 mm and 5 mm. Root mean square (RMS) values for total, low-order, and high-order aberrations were analyzed. Results The mineral oil + HP-Guar formulation significantly reduced total RMS ( p  < 0.05) and low-order RMS ( p  < 0.05) at both 3-mm and 5-mm pupil diameters. Notable reductions were observed in defocus ( Z 2 0 ), vertical astigmatism ( Z 2 2 ), and trefoil ( Z 3 −3 ). Both formulations significantly increased high-order RMS ( p  < 0.05). Conclusions Lipid-based artificial tears provide superior optical quality by reducing total and low-order ocular aberrations, making them preferable for patients with tear film instability. In contrast, HA-based formulations primarily improve hydration with limited impact on optical performance. Artificial tear selection should consider both symptomatic relief and refractive stability, especially for individuals with high visual demands. Clinical Trial Registration This study was registered as a randomized clinical trial on ClinicalTrials.gov under the identifier NCT06784661, titled the ILEACT study.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:2193-8245
2193-6528
DOI:10.1007/s40123-025-01205-z