Improved postprocessing of dynamic glucose-enhanced CEST MRI for imaging brain metastases at 3 T
Background Dynamic glucose-enhanced (DGE) chemical exchange saturation transfer (CEST) has the potential to characterize glucose metabolism in brain metastases. Since the effect size of DGE CEST is small at 3 T (< 1%), measurements of signal-to-noise ratios are challenging. To improve DGE detecti...
Saved in:
Published in | European radiology experimental Vol. 7; no. 1; p. 78 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | English |
Published |
Vienna
Springer Vienna
08.12.2023
Springer Nature B.V SpringerOpen |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Background
Dynamic glucose-enhanced (DGE) chemical exchange saturation transfer (CEST) has the potential to characterize glucose metabolism in brain metastases. Since the effect size of DGE CEST is small at 3 T (< 1%), measurements of signal-to-noise ratios are challenging. To improve DGE detection, we developed an acquisition pipeline and extended image analysis for DGE CEST on a hybrid 3-T positron emission tomography/magnetic resonance imaging system.
Methods
This cross-sectional study was conducted after local ethical approval. Static Z-spectra (from -100 to 100 ppm) were acquired to compare the use of 1.2
versus
2 ppm to calculate static glucose-enhanced (glucoCEST) maps in 10 healthy volunteers before and after glucose infusion. Dynamic CEST images were acquired during glucose infusion. Image analysis was optimized using motion correction, dynamic
B
0
correction, and principal component analysis (PCA) to improve the detection of DGE CEST in the sagittal sinus, cerebrospinal fluid, and grey and white matter. The developed DGE CEST pipeline was applied to four patients diagnosed with brain metastases.
Results
GlucoCEST was strongest in healthy tissues at 2 ppm. Correcting for motion,
B
0,
and use of PCA locally improved DGE maps. A larger contrast between healthy tissues and enhancing regions in brain metastases was found when dynamic
B
0
correction and PCA denoising were applied.
Conclusion
We demonstrated the feasibility of DGE CEST with our developed acquisition and analysis pipeline at 3 T in patients with brain metastases. This work enables a direct comparison of DGE CEST to 18F-fluoro-deoxy-D-glucose positron emission tomography of glucose metabolism in patients with brain metastases.
Relevance statement
Contrast between brain metastasis and healthy brain tissue in DGE CEST MR images is improved by including principle component analysis and dynamic magnetic field correction during postprocessing. This approach enables the detection of increased DGE CEST signal in brain metastasis, if present.
Key points
• Despite the low signal-to-noise ratio, dynamic glucose-enhanced CEST MRI is feasible at 3 T.
• Principal component analyses and dynamic magnetic field correction improve DGE CEST MRI.
• DGE CEST MRI does not consequently show changes in brain metastases compared to healthy brain tissue.
• Increased DGE CEST MRI in brain metastases, if present, shows overlap with contrast enhancement on T1-weighted images.
Graphical Abstract |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 ObjectType-Commentary-3 content type line 23 |
ISSN: | 2509-9280 2509-9280 |
DOI: | 10.1186/s41747-023-00390-5 |