Blood concentrations of d‐ and l‐lactate in healthy rabbits

OBJECTIVES: To determine whole blood and serum concentrations of l‐lactate and serum concentrations of d‐lactate in healthy rabbits and compare three methods of analysis for l‐lactate measurement. METHODS: Prospective study using 25 rabbits. Concentrations of whole blood l‐lactate were measured usin...

Full description

Saved in:
Bibliographic Details
Published inJournal of small animal practice Vol. 55; no. 9; pp. 451 - 456
Main Authors Langlois, I, Planché, A, Boysen, S. R, Abeysekara, S, Zello, G. A
Format Journal Article
LanguageEnglish
Published Oxford, UK Blackwell Publishing Ltd 01.09.2014
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:OBJECTIVES: To determine whole blood and serum concentrations of l‐lactate and serum concentrations of d‐lactate in healthy rabbits and compare three methods of analysis for l‐lactate measurement. METHODS: Prospective study using 25 rabbits. Concentrations of whole blood l‐lactate were measured using a portable analyser and a blood gas analyser. The remainder of the sample was allowed to clot for centrifugation. Serum was stored at −20°C for determination of l‐ and d‐ lactate by high‐performance liquid chromatography. RESULTS: d‐lactate values by high‐performance liquid chromatography were 0 · 17 ± 0 · 08 mmol/L. l‐lactate values were 5 · 1 (±2 · 1) mmol/L by high‐performance liquid chromatography, 6 · 9 (±2 · 7) mmol/L with the portable analyser and 7 · 1 (±1 · 6) mmol/L with the blood gas analyser. No significant difference (P > 0 · 05) was found between the two analysers. Significant difference existed between serum l‐lactate values obtained by high‐performance liquid chromatography and the whole blood values obtained with the blood gas analyser (P < 0 · 01) and portable analyser (P < 0 · 05). CLINICAL SIGNIFICANCE: Serum concentrations of d‐lactate in healthy rabbits are in the range of those of other mammals. l‐lactate values in healthy rabbits are higher compared with other mammals. Good correlation was found between the portable and blood gas analysers for whole blood l‐lactate measurement in healthy rabbits.
Bibliography:http://dx.doi.org/10.1111/jsap.12247
ArticleID:JSAP12247
ark:/67375/WNG-TG8F1FMF-R
istex:482698125EEDAC6C506665A1D6211D505DE90605
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0022-4510
1748-5827
DOI:10.1111/jsap.12247