Confirmatory factor analysis of the Dutch Screening Visual Complaints questionnaire in people with multiple sclerosis

Background Visual complaints among people with multiple sclerosis (pwMS) are common, but often difficult to recognize. The Screening Visual Complaints questionnaire (SVCq) has been developed to screen for visual complaints in people with a neurodegenerative disease, including multiple sclerosis (MS)...

Full description

Saved in:
Bibliographic Details
Published inJournal of patient-reported outcomes Vol. 6; no. 1; p. 36
Main Authors van der Feen, Fleur E., de Haan, Gera A., van der Lijn, Iris, Fuermaier, Anselm B. M., Heersema, Thea J., Meilof, Jan F., Heutink, Joost
Format Journal Article
LanguageEnglish
Published Cham Springer International Publishing 09.04.2022
Springer Nature B.V
SpringerOpen
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background Visual complaints among people with multiple sclerosis (pwMS) are common, but often difficult to recognize. The Screening Visual Complaints questionnaire (SVCq) has been developed to screen for visual complaints in people with a neurodegenerative disease, including multiple sclerosis (MS). A previous study performed a factor analysis in a normal population which revealed an acceptable one-factor model, a three-factor model and a five-factor model within the SVCq. To increase the usability of the SVCq in people with MS, the purpose of the current study was to investigate the fit of the three models in a cohort of pwMS. Results The confirmatory factor analysis on the SVCq in 493 people with MS showed good fit for all the models. The three-factor model ( diminished visual perception , altered visual perception and ocular discomfort ) outperformed the one-factor model. The five-factor model outperformed both models, which showed that dividing the first factor ( diminished visual perception) into three more factors ( function-related , luminance-related and task-related ) has merit. Conclusions All models may be useful in clinical care for pwMS. The one-factor model may give a quick overview of the presence and severity of visual complaints in general. The individual factors, of either the three- or the five factor models, may contribute to a better recognition of the nature of visual complaints in pwMS and may guide further steps in rehabilitation for pwMS with visual complaints.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2509-8020
2509-8020
DOI:10.1186/s41687-022-00443-0