Validation of a patient-specific simulator for laparoscopic renal surgery

Objectives To describe and to validate a novel patient‐specific virtual‐reality based simulator for laparoscopic surgery. Methods Three surgeons carried out 13 preoperative simulations at Yokohama City University Hospital, Yokohama, Kanagawa, Japan, from 2011 to 2012. The procedures included seven n...

Full description

Saved in:
Bibliographic Details
Published inInternational journal of urology Vol. 22; no. 6; pp. 572 - 576
Main Authors Makiyama, Kazuhide, Yamanaka, Hiroyuki, Ueno, Daiki, Ohsaka, Kimito, Sano, Futoshi, Nakaigawa, Noboru, Yao, Masahiro, Kubota, Yoshinobu
Format Journal Article
LanguageEnglish
Published Australia Blackwell Publishing Ltd 01.06.2015
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objectives To describe and to validate a novel patient‐specific virtual‐reality based simulator for laparoscopic surgery. Methods Three surgeons carried out 13 preoperative simulations at Yokohama City University Hospital, Yokohama, Kanagawa, Japan, from 2011 to 2012. The procedures included seven nephrectomies, four partial nephrectomies and two pyeloplasties. We evaluated whether the anatomies reproduced by the simulator matched those encountered during the actual operations. Furthermore, the surgeons were asked to use visual analog scales (from 1 to 5; higher scores are better) to evaluate the anatomical integrity and utility of the simulations, and their intraoperative confidence during the subsequent surgical procedures. Results The simulator reproduced the patients’ anatomies almost perfectly. Only a few minor mistakes were identified. Regarding the surgeons’ evaluations of the system, the mean scores for the anatomical integrity and utility of the simulations, and the surgeons’ intraoperative confidence were 3.4, 4.2 and 4.1, respectively. In all 13 cases, the surgeons were able to carry out preoperative training with ease, and they stated that the simulator was useful for producing preoperative images. Conclusions A patient‐specific simulator for laparoscopic renal surgery has been successfully developed. This system correctly reproduces anatomical structures, and it seems to be a useful preoperative training tool.
Bibliography:ArticleID:IJU12737
istex:9C497FBBC01E266029FAAB5BDB200291190E60FE
ark:/67375/WNG-Z6HKLHJ9-4
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0919-8172
1442-2042
DOI:10.1111/iju.12737