Microelectrode Recordings Validate the Clinical Visualization of Subthalamic-Nucleus Based on 7T Magnetic Resonance Imaging and Machine Learning for Deep Brain Stimulation Surgery

Abstract BACKGROUND Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a proven and effective therapy for the management of the motor symptoms of Parkinson's disease (PD). While accurate positioning of the stimulating electrode is critical for success of this therapy, precise iden...

Full description

Saved in:
Bibliographic Details
Published inNeurosurgery Vol. 84; no. 3; pp. 749 - 757
Main Authors Shamir, Reuben R, Duchin, Yuval, Kim, Jinyoung, Patriat, Remi, Marmor, Odeya, Bergman, Hagai, Vitek, Jerrold L, Sapiro, Guillermo, Bick, Atira, Eliahou, Ruth, Eitan, Renana, Israel, Zvi, Harel, Noam
Format Journal Article
LanguageEnglish
Published United States Oxford University Press 01.03.2019
Copyright by the Congress of Neurological Surgeons
Wolters Kluwer Health, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract BACKGROUND Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a proven and effective therapy for the management of the motor symptoms of Parkinson's disease (PD). While accurate positioning of the stimulating electrode is critical for success of this therapy, precise identification of the STN based on imaging can be challenging. We developed a method to accurately visualize the STN on a standard clinical magnetic resonance imaging (MRI). The method incorporates a database of 7-Tesla (T) MRIs of PD patients together with machine-learning methods (hereafter 7 T-ML). OBJECTIVE To validate the clinical application accuracy of the 7 T-ML method by comparing it with identification of the STN based on intraoperative microelectrode recordings. METHODS Sixteen PD patients who underwent microelectrode-recordings guided STN DBS were included in this study (30 implanted leads and electrode trajectories). The length of the STN along the electrode trajectory and the position of its contacts to dorsal, inside, or ventral to the STN were compared using microelectrode-recordings and the 7 T-ML method computed based on the patient's clinical 3T MRI. RESULTS All 30 electrode trajectories that intersected the STN based on microelectrode-recordings, also intersected it when visualized with the 7 T-ML method. STN trajectory average length was 6.2 ± 0.7 mm based on microelectrode recordings and 5.8 ± 0.9 mm for the 7 T-ML method. We observed a 93% agreement regarding contact location between the microelectrode-recordings and the 7 T-ML method. CONCLUSION The 7 T-ML method is highly consistent with microelectrode-recordings data. This method provides a reliable and accurate patient-specific prediction for targeting the STN.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Undefined-3
ISSN:0148-396X
1524-4040
DOI:10.1093/neuros/nyy212