Gradient nonlinearity correction to improve apparent diffusion coefficient accuracy and standardization in the american college of radiology imaging network 6698 breast cancer trial
Purpose To evaluate a gradient nonlinearity correction (GNC) program for quantitative apparent diffusion coefficient (ADC) measurements on phantom and human subject diffusion‐weighted (DW) magnetic resonance imaging (MRI) scans in a multicenter breast cancer treatment response study Materials and Me...
Saved in:
Published in | Journal of magnetic resonance imaging Vol. 42; no. 4; pp. 908 - 919 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
Blackwell Publishing Ltd
01.10.2015
Wiley Subscription Services, Inc |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Purpose
To evaluate a gradient nonlinearity correction (GNC) program for quantitative apparent diffusion coefficient (ADC) measurements on phantom and human subject diffusion‐weighted (DW) magnetic resonance imaging (MRI) scans in a multicenter breast cancer treatment response study
Materials and Methods
A GNC program using fifth‐order spherical harmonics for gradient modeling was applied retrospectively to qualification phantom and human subject scans. Ice‐water phantoms of known diffusion coefficient were scanned at five different study centers with different scanners and receiver coils. Human in vivo data consisted of baseline and early‐treatment exams on 54 patients from four sites. ADC maps were generated with and without GNC. Regions of interest were defined to quantify absolute errors and changes with GNC over breast imaging positions.
Results
Phantom ADC errors varied with region of interest (ROI) position and scanner configuration; the mean error by configuration ranged from 1.4% to 19.9%. GNC significantly reduced the overall mean error for all sites from 9.9% to 0.6% (P = 0.016). Spatial dependence of GNC was highest in the right‐left (RL) and anterior‐posterior (AP) directions. Human subject mean tumor ADC was reduced 0.2 to 12% by GNC at different sites. By regression, every 1‐cm change in tumor ROI position between baseline and follow‐up visits resulted in an estimated change of 2.4% in the ADC early‐treatment response measurement.
Conclusion
GNC is effective for removing large, system‐dependent errors in quantitative breast DWI. GNC may be important in ensuring reproducibility in multicenter studies and in reducing errors in longitudinal treatment response measures arising from spatial variations in tumor position between visits. J. Magn. Reson. Imaging 2015;42:908–919. |
---|---|
Bibliography: | ark:/67375/WNG-K8GX2H3K-2 NCI - No. U01 CA079778; No. CA080098 to ACRIN ArticleID:JMRI24883 National Institutes of Health / National Cancer Institute (NIH/NCI) - No. UO1 CA151235; No. U01 CA166104 istex:CF582C94D83AAE50A9C02808455E472B774BEF00 ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 ObjectType-Article-2 ObjectType-Feature-1 content type line 23 |
ISSN: | 1053-1807 1522-2586 1522-2586 |
DOI: | 10.1002/jmri.24883 |