Diagnostic determination system for high-risk screening for inborn errors of bile acid metabolism based on an analysis of urinary bile acids using gas chromatography-mass spectrometry: Results for 10 years in Japan

Background:  Some patients with cholestasis of unknown cause may have inborn errors of bile acid metabolism (IEBAM) thus causing abnormalities of bile acid biosynthesis. Although seven types of bile acid synthetic defects have thus far been reported for this disorder, no detailed information on its...

Full description

Saved in:
Bibliographic Details
Published inPediatrics international Vol. 51; no. 4; pp. 535 - 543
Main Authors Nittono, Hiroshi, Takei, Hajime, Unno, Atsushi, Kimura, Akihiko, Shimizu, Toshiaki, Kurosawa, Takao, Tohma, Sadahiko, Une, Mizuho
Format Journal Article
LanguageEnglish
Published Melbourne, Australia Blackwell Publishing Asia 01.08.2009
Blackwell Publishing Ltd
Subjects
Online AccessGet full text
ISSN1328-8067
1442-200X
1442-200X
DOI10.1111/j.1442-200X.2008.02799.x

Cover

More Information
Summary:Background:  Some patients with cholestasis of unknown cause may have inborn errors of bile acid metabolism (IEBAM) thus causing abnormalities of bile acid biosynthesis. Although seven types of bile acid synthetic defects have thus far been reported for this disorder, no detailed information on its incidence and so on in Japan is yet available. In order to elucidate the current status of IEBAM in Japan, in July 1996 a diagnostic determination system was established for high‐risk screening for IEBAM. Methods:  Urinary bile acids were analyzed on gas chromatography–mass spectrometry (GC‐MS) and quantitative analysis was done using selected ion monitoring (SIM). Results and conclusions:  In a total of 576 samples analyzed over the 10 year period prior to June 2005, 159 patients were found with cholestasis of unknown etiology. Of these patients, 10 (6.3%) were found to have IEBAM by this system, while 91 (61.1%) had cholestasis without a definitive diagnosis. This diagnostic determination system with GC‐MS of urinary bile acids is therefore considered useful for detecting IEBAM.
Bibliography:ArticleID:PED2799
ark:/67375/WNG-3HKCRL67-5
istex:66A302B4B33370165A4C35FC5202C1EEF3422BFC
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 14
ObjectType-Article-2
content type line 23
ObjectType-Case Study-2
ObjectType-Feature-4
ObjectType-Report-1
ObjectType-Article-3
ISSN:1328-8067
1442-200X
1442-200X
DOI:10.1111/j.1442-200X.2008.02799.x