Assessment of Becton Dickinson Plain and Serum Separator Tubes in Measurement of 25-Hydroxyvitamin D3 (25OHD3) by HPLC and Immunoassay Methods

Background The accuracy of 25‐hydroxyvitamin D3 (25OHD3) measurement on specimens collected into serum separator tubes (SSTs) has been questioned because of possible interference by the gel. Possible interference was investigated in SSTs from Becton Dickinson (BD). Design and methods Blood specimens...

Full description

Saved in:
Bibliographic Details
Published inJournal of clinical laboratory analysis Vol. 30; no. 1; pp. 32 - 35
Main Authors Borai, Anwar, Bahijri, Suhad, Livingstone, Callum, Nawajha, Mustafa, Bawazeer, Ali, Baarmah, Ziad, Shanaa, Ahmed, Kadam, Ibrahim, Abdelaal, Mohamed
Format Journal Article
LanguageEnglish
Published United States Blackwell Publishing Ltd 01.01.2016
John Wiley & Sons, Inc
John Wiley and Sons Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background The accuracy of 25‐hydroxyvitamin D3 (25OHD3) measurement on specimens collected into serum separator tubes (SSTs) has been questioned because of possible interference by the gel. Possible interference was investigated in SSTs from Becton Dickinson (BD). Design and methods Blood specimens were collected simultaneously from 50 normal subjects into plain tubes and SSTs. 25OHD3 was assayed on serum using high performance liquid chromatography (Chromsystems), and Architect (Abbott) and Liaison (Diasorin) immunoassays. Results There were no significant differences between 25OHD3 results (means ± SE, nmol/l) obtained from specimens collected into plain tubes and SSTs assayed by HPLC (39.0 ± 2.7 vs. 39.3 ± 2.7), Liaison (32.9 ± 2.2 vs. 32.8 ± 2.3), or Architect (43.1 ± 2.8 vs. 43.2 ± 2.8). In specimens collected into plain tubes and SSTs, 25OHD3 measurements by HPLC correlated significantly (P < 0.0001) with those from the Architect (r = 0.895, r = 0.908) and Liaison (r = 0.907, r = 0.913), respectively. Conclusions The gel in SSTs (BD) does not interfere with the measurement of 25OHD3 by HPLC or common immunoassays. This important finding may enable clinical laboratories to make cost savings by using SSTs without concerns about inaccuracy.
Bibliography:ark:/67375/WNG-FTM4Z50G-P
istex:A304A0B35F092F70F9CFB651FDF2F6854F24DD30
King Abdullah International Medical Research Center
ArticleID:JCLA21805
Grant sponsor: King Abdullah International Medical Research Center.
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0887-8013
1098-2825
1098-2825
DOI:10.1002/jcla.21805