96-Channel receive-only head coil for 3 Tesla: Design optimization and evaluation

The benefits and challenges of highly parallel array coils for head imaging were investigated through the development of a 3T receive‐only phased‐array head coil with 96 receive elements constructed on a close‐fitting helmet‐shaped former. We evaluated several designs for the coil elements and match...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 62; no. 3; pp. 754 - 762
Main Authors Wiggins, Graham C., Polimeni, Jonathan R., Potthast, Andreas, Schmitt, Melanie, Alagappan, Vijay, Wald, Lawrence L.
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc., A Wiley Company 01.09.2009
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The benefits and challenges of highly parallel array coils for head imaging were investigated through the development of a 3T receive‐only phased‐array head coil with 96 receive elements constructed on a close‐fitting helmet‐shaped former. We evaluated several designs for the coil elements and matching circuitry, with particular attention to sources of signal‐to‐noise ratio (SNR) loss, including various sources of coil loading and coupling between the array elements. The SNR and noise amplification (g‐factor) in accelerated imaging were quantitatively evaluated in phantom and human imaging and compared to a 32‐channel array built on an identical helmet‐shaped former and to a larger commercial 12‐channel head coil. The 96‐channel coil provided substantial SNR gains in the distal cortex compared to the 12‐ and 32‐channel coils. The central SNR for the 96‐channel coil was similar to the 32‐channel coil for optimum SNR combination and 20% lower for root‐sum‐of‐squares combination. There was a significant reduction in the maximum g‐factor for 96 channels compared to 32; for example, the 96‐channel maximum g‐factor was 65% of the 32‐channel value for acceleration rate 4. The performance of the array is demonstrated in highly accelerated brain images. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.
Bibliography:ark:/67375/WNG-0C826HNS-B
National Institutes of Health - No. P41RR014075; No. R01EB006847; No. R01EB000790
Institute for Mental Illness and Neuroscience Discovery (MIND)
istex:8ADBFE6FC4D921926297EDF6F6CC6AD1B6ED4025
ArticleID:MRM22028
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Article-2
ObjectType-Feature-1
ISSN:0740-3194
1522-2594
1522-2594
DOI:10.1002/mrm.22028