Long-term field test of solar PV power generation using one-axis 3-position sun tracker

► The present study carried out outdoor experiments to measure the daily-total and long-term PV energy generation of the 1A-3P tracking PV and the fixed PV simultaneously. ► The test in the particular days shows that the 1A-3P performs very close to 2-axis continuous tracking PV. ► The daily-total p...

Full description

Saved in:
Bibliographic Details
Published inSolar energy Vol. 85; no. 9; pp. 1935 - 1944
Main Authors Huang, B.J., Ding, W.L., Huang, Y.C.
Format Journal Article
LanguageEnglish
Published Kidlington Elsevier Ltd 01.09.2011
Elsevier
Pergamon Press Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:► The present study carried out outdoor experiments to measure the daily-total and long-term PV energy generation of the 1A-3P tracking PV and the fixed PV simultaneously. ► The test in the particular days shows that the 1A-3P performs very close to 2-axis continuous tracking PV. ► The daily-total performance of 1X-3P tracking PV is very close to 1-axis continuous tracking PV. ► The long-term test for 13 months shows that 1A-3P tracking PV generates 23.6% more energy than the fixed PV in Taipei. ► If 1A-3P tracking PV is used in high irradiation area, the long-term energy generation will be very close to 2-axis continuous tracking PV. The 1 axis-3 position (1A-3P) sun tracking PV was built and tested to measure the daily and long-term power generation of the solar PV system. A comparative test using a fixed PV and a 1A-3P tracking PV was carried out with two identical stand-alone solar-powered LED lighting systems. The field test in the particular days shows that the 1A-3P tracking PV can generate 35.8% more electricity than the fixed PV in a partly-cloudy weather with daily-total solar irradiation H T = 11.7 MJ/m 2 day, or 35.6% in clear weather with H T = 18.5 MJ/m 2 day. This indicates that the present 1A-3P tracking PV can perform very close to a dual-axis continuous tracking PV ( Kacira et al., 2004). The long-term outdoor test results have shown that the increase of daily power generation of 1A-3P tracking PV increases with increasing daily-total solar irradiation. The increase of monthly-total power generation for 1A-3P sun tracking PV is between 18.5–28.0%. The total power generation increase in the test period from March 1, 2010 to March 31, 2011, is 23.6% in Taipei (an area of low solar energy resource). The long-term performance of the present 1X-3P tracking PV is shown very close to the 1-axis continuous tracking PV in Taiwan ( Chang, 2009). If the 1A-3P tracking PV is used in the area of high solar energy resource with yearly-average H T > 17 MJ/m 2 day, the increase of total long-term power generation with respect to fixed PV will be higher than 37.5%. This is very close to that of dual-axis continuous tracking PV. The 1A-3P tracker can be easily mounted on the wall of a building. The cost of the whole tracker is about the same as the regular mounting cost of a conventional rooftop PV system. This means that there is no extra cost for 1A-3P PV mounted on buildings. The 1A-3P PV is quite suitable for building-integrated applications.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0038-092X
1471-1257
DOI:10.1016/j.solener.2011.05.001