Study of the effect of the strategy of heating on the mudejar church of Santa Maria in Ateca (Spain) for preventive conservation of the altarpiece surroundings

The mudéjar church of Santa María (Ateca) is valuable for its architecture and the altarpiece contained inside. Ateca is a village with continental climate characterized by cold winters and hot summers. In this paper we are interested in analysing the effect of temperature and relative humidity (RH)...

Full description

Saved in:
Bibliographic Details
Published inSensors (Basel, Switzerland) Vol. 13; no. 9; pp. 11407 - 11423
Main Authors García-Diego, Fernando-Juan, Fernández-Navajas, Angel, Beltrán, Pedro, Merello, Paloma
Format Journal Article
LanguageEnglish
Published Switzerland MDPI AG 26.08.2013
MDPI
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The mudéjar church of Santa María (Ateca) is valuable for its architecture and the altarpiece contained inside. Ateca is a village with continental climate characterized by cold winters and hot summers. In this paper we are interested in analysing the effect of temperature and relative humidity (RH) changes produced by the heating system on the altarpiece. Therefore, a monitoring system of 15 temperature and 15 relative humidity sensors was installed with a recording frequency of a data point per minute. The main contribution of this paper is the quantitative study of the effect of the heating system on the thermo-hygrometric parameters using statistical techniques such as ANOVA, mean daily trajectories or bivariate plots, and the proposal of an innovative dynamic contour plot. As results, the heating system produces a substantial increase (decrease) of temperature (RH) causing an hourly variation of these physical parameters detrimental to the conservation of the altarpiece, especially in its higher areas.
Bibliography:All authors contributed equally to this work.
ISSN:1424-8220
1424-8220
DOI:10.3390/s130911407