Effects of individualized PEEP obtained by two different titration methods on postoperative atelectasis in obese patients: study protocol for a randomized controlled trial
Abstract Background The incidence of postoperative pulmonary complications (PPCs) is higher in obese patients undergoing general anesthesia and mechanical ventilation due to the reduction of oxygen reserve, functional residual capacity, and lung compliance. Individualized positive end-expiratory pre...
Saved in:
Published in | Current controlled trials in cardiovascular medicine Vol. 22; no. 1; p. 704 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
London
BioMed Central Ltd
15.10.2021
BioMed Central BMC |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Abstract
Background
The incidence of postoperative pulmonary complications (PPCs) is higher in obese patients undergoing general anesthesia and mechanical ventilation due to the reduction of oxygen reserve, functional residual capacity, and lung compliance. Individualized positive end-expiratory pressure (iPEEP) along with other lung-protective strategies is effective in alleviating postoperative atelectasis. Here, we compared the best static lung compliance (Cstat) titration of iPEEP with electrical impedance tomography (EIT) titration to observe their effects on postoperative atelectasis in obese patients undergoing laparoscopic surgery.
Methods
A total number of 140 obese patients with BMI ≥ 32.5kg/m
2
undergoing elective laparoscopic gastric volume reduction and at moderate to high risk of developing PPCs will be enrolled and randomized into the optimal static lung compliance-directed iPEEP group and EIT titration iPEEP group. The primary endpoint will be pulmonary atelectasis measured and calculated by EIT immediately after extubation and 2 h after surgery. Secondary endpoints will be intraoperative oxygenation index, organ dysfunction, incidence of PPCs, hospital expenses, and length of hospital stay.
Discussion
Many iPEEP titration methods effective for normal weight patients may not be appropriate for obese patients. Although EIT-guided iPEEP titration is effective in obese patients, its high price and complexity limit its application in many clinical facilities. This trial will test the efficacy of iPEEP via the optimal static lung compliance-guided titration procedure by comparing it with EIT-guided PEEP titration. The results of this trial will provide a feasible and convenient method for anesthesiologists to set individualized PEEP for obese patients during laparoscopic surgery.
Trial registration
ClinicalTrials.gov
ChiCTR2000039144
. Registered on October 19, 2020 |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Undefined-1 ObjectType-Feature-3 content type line 23 |
ISSN: | 1745-6215 1745-6215 |
DOI: | 10.1186/s13063-021-05671-1 |