Mediolateral oversizing influences pain, function, and flexion after TKA

Purpose Manufacturers of total knee arthroplasty (TKA) have introduced narrower femurs to improve bone-implant fit. However, few studies have reported the clinical consequences of mediolateral oversizing. Our hypothesis was that component oversizing negatively influences the results after TKA. Metho...

Full description

Saved in:
Bibliographic Details
Published inKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA Vol. 21; no. 10; pp. 2314 - 2324
Main Authors Bonnin, Michel P., Schmidt, Axel, Basiglini, Luca, Bossard, Nadine, Dantony, Emmanuelle
Format Journal Article
LanguageEnglish
Published Berlin/Heidelberg Springer Berlin Heidelberg 01.10.2013
Springer Nature B.V
Springer Verlag
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose Manufacturers of total knee arthroplasty (TKA) have introduced narrower femurs to improve bone-implant fit. However, few studies have reported the clinical consequences of mediolateral oversizing. Our hypothesis was that component oversizing negatively influences the results after TKA. Methods One hundred and twelve prospectively followed patients with 114 consecutive TKA (64 females and 50 males) were retrospectively assessed. The mean age of the patients was 72 years (range, 56 to 85 years). The dimensions of the femur and tibia were measured on a preoperative CT-scan and were compared with those of the implanted TKA. The influence of size variation on the clinical outcomes 1 year after surgery was assessed. Results Mediolateral overhang was observed in at least one area in 66 % of the femurs (84 % in females and 54 % in males) and 61 % of the tibia (81 % in females and 40 % in males). Twenty-two patients presented no overhang in any area and 16 had overhang in all studied zones. The increase in the Pain and KOOS scores were 43 ± 21 and 36 ± 18 in the patients without overhang and 31 ± 19 and 25 ± 13 in patients with overhang ( p  = 0.033; p  = 0.032). Knee flexion was 127° ± 7 and 121° ± 11, respectively. Regression and latent class analysis showed a significant negative correlation between overall oversizing and overall outcome. Conclusions This study confirms that oversizing may lead to worse clinical results in TKA. The clinical consequences are that surgeons should pay attention not to oversize implants during implantation nd that oversizing should be ruled out in case of so called unexplained pain. Level of evidence IV.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
ObjectType-Feature-1
PMCID: PMC3777155
ISSN:0942-2056
1433-7347
DOI:10.1007/s00167-013-2443-x