Validation of a new serum granulocyte–macrophage colony-stimulating factor autoantibody testing kit

Very recently, a modest but significant efficacy of granulocyte–macrophage colony-stimulating factor (GM-CSF) inhalation therapy for the treatment of mild to moderate autoimmune pulmonary alveolar proteinosis (aPAP) has been reported. As the ability to measure the level of GM-CSF autoantibody (GMAb)...

Full description

Saved in:
Bibliographic Details
Published inERJ open research Vol. 6; no. 1; p. 259
Main Authors Nakata, Koh, Sugi, Tatsuki, Kuroda, Keiko, Yoshizawa, Kazutaka, Takada, Toshinori, Tazawa, Ryushi, Ueda, Takahiro, Aoki, Ami, Abe, Mitsuhiro, Tatsumi, Koichiro, Eda, Ryosuke, Kondoh, Shotaro, Morimoto, Konosuke, Tanaka, Takeshi, Yamaguchi, Etsuro, Takahashi, Ayumu, Oda, Miku, Ishii, Haruyuki, Izumi, Shinyu, Sugiyama, Haruhito, Nakagawa, Atsushi, Tomii, Keisuke, Suzuki, Masaru, Konno, Satoshi, Ohkouchi, Shinya, Hirano, Taizou, Handa, Tomohiro, Hirai, Toyohiro, Inoue, Yoshikazu, Arai, Toru, Asakawa, Katsuaki, Sakagami, Takuro, Tanaka, Takahiro, Mikami, Ayako, Kitamura, Nobutaka
Format Journal Article
LanguageEnglish
Published England European Respiratory Society 01.01.2020
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Very recently, a modest but significant efficacy of granulocyte–macrophage colony-stimulating factor (GM-CSF) inhalation therapy for the treatment of mild to moderate autoimmune pulmonary alveolar proteinosis (aPAP) has been reported. As the ability to measure the level of GM-CSF autoantibody (GMAb) in the serum is required to decide the indication for this therapy, we developed a high-performance GMAb testing kit for clinical use. As the kit succeeded in reducing nonspecific IgG binding to the ELISA plate, the predictive performance shown in the training study to discriminate aPAP patients from healthy subjects was perfect, providing a cut-off value of 1.65 U·mL −1 in 78 patients with aPAP and 90 healthy subjects in an operator-blinded manner using logistic regression analysis. As in the validation study, serum samples from another 213 patients with aPAP were also blinded and evaluated in an operator-blinded manner against external 207 samples from patients with other types of PAP and patients exhibiting various ground-glass opacities on chest high-resolution computed tomography that require discrimination from PAP. The logistic regression analysis of these validation data sets revealed values of 97.6% and 100% for specificity and sensitivity, respectively. Thus, this new GMAb testing kit is reliable for the diagnosis of aPAP and differential diagnosis of other lung diseases.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2312-0541
2312-0541
DOI:10.1183/23120541.00259-2019