Ultrasonographic and biochemical markers of human fetal cardiac dysfunction in placental insufficiency

Placental insufficiency may lead to fetal cardiovascular compromise. We sought to determine whether ultrasonographic parameters of fetal cardiovascular function correlate with umbilical arterial levels of biochemical markers of myocardial dysfunction and damage in placental insufficiency. In 48 fetu...

Full description

Saved in:
Bibliographic Details
Published inCirculation (New York, N.Y.) Vol. 105; no. 17; pp. 2058 - 2063
Main Authors MÄKIKALLIO, Kaarin, VUOLTEENAHO, Olli, JOUPPILA, Pentti, RÄSÄNEN, Juha
Format Journal Article
LanguageEnglish
Published Hagerstown, MD Lippincott Williams & Wilkins 30.04.2002
American Heart Association, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Placental insufficiency may lead to fetal cardiovascular compromise. We sought to determine whether ultrasonographic parameters of fetal cardiovascular function correlate with umbilical arterial levels of biochemical markers of myocardial dysfunction and damage in placental insufficiency. In 48 fetuses with placental insufficiency, umbilical artery blood was obtained at delivery for assessment of N-terminal peptide of proatrial natriuretic peptide (NT-proANP) and cardiac troponin-T (cTnT). Group 1 fetuses (n=12) had normal NT-proANP and cTnT serum concentrations. Group 2 fetuses (n=25) showed increased NT-proANP (>1145 pmol/L) and normal cTnT values. Group 3 fetuses (n=11) had increased NT-proANP and cTnT (>0.10 ng/mL) levels. The ultrasonographic parameters of fetal cardiovascular function were compared between the groups. Pulsatility indices for veins of the ductus venosus, left hepatic vein, and inferior vena cava correlated significantly with NT-proANP levels. In group 3, ductus venosus, left hepatic vein, and inferior vena cava pulsatility indices for veins were higher (P<0.01) than in groups 1 and 2. The proportion of left ventricular cardiac output of combined cardiac output was greater (P<0.05) and that of right ventricle was smaller (P<0.05) in group 3 than in group 2. In group 3, tricuspid regurgitation was noted most often (P<0.05), and right ventricular fractional shortening was less (P<0.01) than in group 2. Pulsatility in human fetal systemic veins correlated significantly with the cardiac secretion of ANP. Fetuses with myocardial damage demonstrate increased systemic venous pressure, a change in the distribution of cardiac output toward the left ventricle, and a rise in right ventricular afterload.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0009-7322
1524-4539
DOI:10.1161/01.cir.0000015505.24187.fa