Local liquid holdups and hysteresis in a 2-D packed bed using X-ray radiography

An X‐ray visualization technique has been used for the quantitative determination of local liquid holdups distribution and liquid holdup hysteresis in a nonwetting two‐dimensional (2‐D) packed bed. A medical diagnostic X‐ray unit has been used to image the local holdups in a 2‐D cold model having a...

Full description

Saved in:
Bibliographic Details
Published inAIChE journal Vol. 51; no. 8; pp. 2178 - 2189
Main Authors Basavaraj, M. G., Gupta, G. S., Naveen, K., Rudolph, V., Bali, R.
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc., A Wiley Company 01.08.2005
Wiley Subscription Services
American Institute of Chemical Engineers
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:An X‐ray visualization technique has been used for the quantitative determination of local liquid holdups distribution and liquid holdup hysteresis in a nonwetting two‐dimensional (2‐D) packed bed. A medical diagnostic X‐ray unit has been used to image the local holdups in a 2‐D cold model having a random packing of expanded polystyrene beads. An aqueous barium chloride solution was used as a fluid to achieve good contrast on X‐ray images. To quantify the local liquid holdup, a simple calibration technique has been developed that can be used for most of the radiological methods such as gamma ray and neutron radiography. The global value of total liquid holdup, obtained by X‐ray method, has been compared with two conventional methods: drainage and tracer response. The X‐ray technique, after validation, has been used to visualize and quantify the liquid hysteresis phenomena in a packed bed. The liquid flows in preferred paths or channels that carry droplets/rivulets of increasing size and number as the liquid flow rate is increased. When the flow is reduced, these paths are retained and the higher liquid holdup that persists in these regions leads to the holdup hysteresis effect. Holdup in some regions of the packed bed may be an order of magnitude higher than average at a particular flow rate. © 2005 American Institute of Chemical Engineers AIChE J, 2005
Bibliography:Council of Scientific and Industrial Research (CSIR), India - No. 22(0361)/02/EMR-II
ark:/67375/WNG-WD5BDZ6V-2
istex:A2953848FC1288A4925F5A6805E7354B275FAD89
ArticleID:AIC10481
R. Bali was a summer student at the Dept. of Metallurgy, Indian Institute of Science, Bangalore, India.
M. G. Basavaraj, a graduate student at the Dept. of Metallurgy, Indian Institute of Science, Bangalore, India, is currently at the Dept. of Chemical Engineering, K.U. Leuven, Leuven B‐3001, Belgium.
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:0001-1541
1547-5905
DOI:10.1002/aic.10481