Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity

To evaluate the reproducibility of real-time shear wave elastography in assessing liver elasticity in healthy volunteers. Forty-two volunteers were studied in day 1. Shear wave elastography studies were performed by using the ultrasound system Aixplorer™ (SuperSonic Imagine S.A., Aix-en-Provence, Fr...

Full description

Saved in:
Bibliographic Details
Published inEuropean journal of radiology Vol. 81; no. 11; pp. 3102 - 3106
Main Authors Ferraioli, Giovanna, Tinelli, Carmine, Zicchetti, Mabel, Above, Elisabetta, Poma, Gianluigi, Di Gregorio, Marta, Filice, Carlo
Format Journal Article
LanguageEnglish
Published Ireland Elsevier Ireland Ltd 01.11.2012
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To evaluate the reproducibility of real-time shear wave elastography in assessing liver elasticity in healthy volunteers. Forty-two volunteers were studied in day 1. Shear wave elastography studies were performed by using the ultrasound system Aixplorer™ (SuperSonic Imagine S.A., Aix-en-Provence, France) with a convex broadband probe. Measurements were carried by two operators, an expert (operator 1) and a novice (operator 2). Examinations were performed on the right lobe of the liver. Each operator performed 10 consecutive measurements in each volunteer. In a subset of volunteers (n=18) measurements were performed twice on two different days (day 1 and day 2). Intraobserver and interobserver agreement were assessed by intraclass correlation coefficient. Intraobserver agreement between measurements performed in the same subject in the same day (day 1 or day 2) showed intraclass correlation coefficient values of 0.95 (95% confidence interval, 0.93–0.98) and 0.93 (95% confidence interval, 0.90–0.96) for operator 1 and operator 2, respectively. Intraobserver agreement between measurements performed in the same subject in different days showed intraclass correlation coefficient values of 0.84 (95% confidence interval, 0.69–0.98) and 0.65 (95% confidence interval, 0.39–0.91) for operator 1 and operator 2, respectively. Interobserver agreement was 0.88 (95% confidence interval, 0.82–0.94). The results of this study show that shear wave elastography is a reliable and reproducible noninvasive method for the assessment of liver elasticity. Expert operator had higher reproducibility of measurements over time than novice operator.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0720-048X
1872-7727
1872-7727
DOI:10.1016/j.ejrad.2012.05.030