Pulpal temperature rise during light-activated bleaching

The purpose of this study was to measure intrapulpal temperature rise induced by two kinds of bleaching gels when the tooth was exposed to a variety of light‐curing units and a diode laser in vitro. The root portions of 80 extracted intact human maxillary central incisors were sectioned with a carbo...

Full description

Saved in:
Bibliographic Details
Published inJournal of biomedical materials research. Part B, Applied biomaterials Vol. 72B; no. 2; pp. 254 - 259
Main Authors Eldeniz, Ayçe Unverdi, Usumez, Aslihan, Usumez, Serdar, Ozturk, Nilgun
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc., A Wiley Company 15.02.2005
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The purpose of this study was to measure intrapulpal temperature rise induced by two kinds of bleaching gels when the tooth was exposed to a variety of light‐curing units and a diode laser in vitro. The root portions of 80 extracted intact human maxillary central incisors were sectioned with a carborundum disk approximately 2 mm below the cementoenamel junction perpendicular to the long axis of the teeth. Two bleaching agents containing heat‐enhancing colorant was applied to the labial surface. Light‐curing units used were a conventional halogen (40 s), a high‐intensity halogen (30 s), a light‐emitting diode unit (40 s), and a diode laser (15 s). The temperature rise was measured in the pulpal chamber with a J‐type thermocouple wire that was connected to a data logger. Ten specimens were used for each system and bleaching‐agent combination. Differences between the starting temperature and highest temperature reading were taken and the calculated temperature changes were averaged to determine the mean value in temperature rise. Temperature rise values were compared using two‐way analysis of variance (ANOVA) at a preset α of 0.05. Temperature rise varied significantly depending on curing unit and diode laser used. The diode laser induced significantly higher temperature increases than any other curing unit (11.7°C). The light‐emitting diode unit produced the lowest temperature changes (6.0°C); however, there were no statistically significant differences among the curing units and there were no statistically significant differences between bleaching agents. Light activation of bleaching materials with diode laser caused higher temperature changes as compared to other curing units and the temperature rise detected was viewed as critical for pulpal health. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 72B: 254–259, 2005
Bibliography:istex:BF033FEC61F7732AC63F375F0933D4076F86572C
ark:/67375/WNG-FMBM20ZX-B
ArticleID:JBM30144
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1552-4973
1552-4981
DOI:10.1002/jbm.b.30144