Effect of Different Ablation Settings on Acute Complications Using the Novel Irrigated Multipolar Radiofrequency Ablation Catheter (nMARQ)

Effects of Different Energy Settings in nMARQ Ablation Background Single‐shot ablation devices for pulmonary vein isolation (PVI) in patients with symptomatic atrial fibrillation (AF) have been increasingly used in clinical practice. Objective A novel mapping‐system integrated irrigated multipolar c...

Full description

Saved in:
Bibliographic Details
Published inJournal of cardiovascular electrophysiology Vol. 26; no. 10; pp. 1063 - 1068
Main Authors DENEKE, THOMAS, MÜLLER, PATRICK, HALBFAß, PHILIPP, SZÖLLÖSI, ATILLA, ROOS, MARKUS, KRUG, JOACHIM, FOCHLER, FRANZISKA, SCHADE, ANJA, SCHMITT, RAINER, CHRISTOPOULOS, GEORGIOS, MÜGGE, ANDREAS, NENTWICH, KARIN
Format Journal Article
LanguageEnglish
Published United States Blackwell Publishing Ltd 01.10.2015
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Effects of Different Energy Settings in nMARQ Ablation Background Single‐shot ablation devices for pulmonary vein isolation (PVI) in patients with symptomatic atrial fibrillation (AF) have been increasingly used in clinical practice. Objective A novel mapping‐system integrated irrigated multipolar circular ablation catheter (nMARQ) has been introduced for PVI but data on larger patient cohorts on acute safety and efficacy are lacking. Methods A total of 145 consecutive patients undergoing AF ablation treated with the nMARQ underwent endoscopic evaluation of esophageal thermal damage (EDEL) and brain MRI for detection of silent cerebral events (SCE). During the course of our experience different modifications of the ablation strategy, including energy delivery at the left atrial posterior wall, were evaluated. Results Effective PVI was achieved in 99% of all PVs during a mean procedure‐duration of 115 (±36) minutes and ablation‐duration of 18 (±8) minutes. Acute major complications occurred in 3 patients (2.1%) and asymptomatic complications like SCE in 26% and EDEL in 21%. There was a significant reduction in EDEL when not using a thermal esophageal probe (0% vs. 28%, P < 0.0001). Ablation under oral anticoagulation led to lower SCE incidences compared to interrupted anticoagulation regimen (15% vs. 31%, P = 0.7). Out of 65 patients with completed 12‐month follow‐up, 43 (66%) were in stable sinus rhythm. Conclusions PVI using the nMARQ is safe and effective in patients with symptomatic AF. Not using an esophageal temperature probe during ablation has relevantly reduced the incidence of EDEL. Ablations under continued oral anticoagulation have reduced incidence of SCE. Further studies on long‐term efficacy are needed.
Bibliography:istex:C2E7E42D77BF5F9C8183F8BB6ECF6520CEDD1D2F
ArticleID:JCE12736
ark:/67375/WNG-X59571GP-L
Other authors: No disclosures.
T. Deneke has received an educational grant from Biosense Webster and speaker's honoraria.
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1045-3873
1540-8167
DOI:10.1111/jce.12736