Micropulse versus continuous wave transscleral diode cyclophotocoagulation in refractory glaucoma: a randomized exploratory study

Background The aim of this study was to compare the efficacy and safety of micropulse and continuous wave diode transscleral cyclophotocoagulation in refractory glaucoma. Design Randomized, comparative, exploratory study in a tertiary hospital setting. Participants Patients with refractory, end‐stag...

Full description

Saved in:
Bibliographic Details
Published inClinical & experimental ophthalmology Vol. 43; no. 1; pp. 40 - 46
Main Authors Aquino, Maria Cecilia D, Barton, Keith, Tan, Anna Marie WT, Sng, Chelvin, Li, Xiang, Loon, Seng Chee, Chew, Paul TK
Format Journal Article
LanguageEnglish
Published Australia Blackwell Publishing Ltd 01.01.2015
Wiley Subscription Services, Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background The aim of this study was to compare the efficacy and safety of micropulse and continuous wave diode transscleral cyclophotocoagulation in refractory glaucoma. Design Randomized, comparative, exploratory study in a tertiary hospital setting. Participants Patients with refractory, end‐stage glaucoma. Methods Forty‐eight patients were randomized to either treatment. The intraocular pressure, visual acuity, number of medicines and repeat treatment were monitored for 18 months. Complications that include visual acuity decline, prolonged anterior chamber inflammation, phthisis bulbi, scleral thinning and ocular pain were noted. Main Outcome Measure Intraocular pressure between 6 and 21 mmHg and at least a 30% reduction with or without anti‐glaucoma medications after 18 months. Results A successful primary outcome was achieved in 75% of patients who underwent micropulse cyclophotocoagulation and 29% of patients who received continuous wave cyclophotocoagulation after 12 months (P < 0.01). At 18 months, successful outcome was 52% and 30% (P = 0.13), respectively. The mean intraocular pressure was reduced by 45% in both groups (P = 0.70) from a baseline of 36.5 mmHg and 35.0 mmHg (P = 0.50) after 17.5 ± 1.6 months (range 16–19) follow up. No significant difference in retreatment rates or number of intraocular pressure lowering medications was noted. The ocular complication rate was higher in continuous wave treated eyes (P = 0.01). Conclusion Diode transscleral cyclophotocoagulation in both micropulse and continuous modes was effective in lowering intraocular pressure. The micropulse mode provided a more consistent and predictable effect in lowering intraocular pressure with minimal ocular complications.
Bibliography:ArticleID:CEO12360
ark:/67375/WNG-Q7QG2S94-T
istex:52DF21201FAAD9830CD39EDF181296BFA3722AE8
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-News-1
ObjectType-Feature-3
content type line 23
ISSN:1442-6404
1442-9071
DOI:10.1111/ceo.12360