Identification of gene expression predictors of occupational benzene exposure

Previously, using microarrays and mRNA-Sequencing (mRNA-Seq) we found that occupational exposure to a range of benzene levels perturbed gene expression in peripheral blood mononuclear cells. In the current study, we sought to identify gene expression biomarkers predictive of benzene exposure below 1...

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 13; no. 10; p. e0205427
Main Authors Schiffman, Courtney, McHale, Cliona M., Hubbard, Alan E., Zhang, Luoping, Thomas, Reuben, Vermeulen, Roel, Li, Guilan, Shen, Min, Rappaport, Stephen M., Yin, Songnian, Lan, Qing, Smith, Martyn T., Rothman, Nathaniel
Format Journal Article
LanguageEnglish
Published United States Public Library of Science 09.10.2018
Public Library of Science (PLoS)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Previously, using microarrays and mRNA-Sequencing (mRNA-Seq) we found that occupational exposure to a range of benzene levels perturbed gene expression in peripheral blood mononuclear cells. In the current study, we sought to identify gene expression biomarkers predictive of benzene exposure below 1 part per million (ppm), the occupational standard in the U.S. First, we used the nCounter platform to validate altered expression of 30 genes in 33 unexposed controls and 57 subjects exposed to benzene (<1 to ≥5 ppm). Second, we used SuperLearner (SL) to identify a minimal number of genes for which altered expression could predict <1 ppm benzene exposure, in 44 subjects with a mean air benzene level of 0.55±0.248 ppm (minimum 0.203ppm). nCounter and microarray expression levels were highly correlated (coefficients >0.7, p<0.05) for 26 microarray-selected genes. nCounter and mRNA-Seq levels were poorly correlated for 4 mRNA-Seq-selected genes. Using negative binomial regression with adjustment for covariates and multiple testing, we confirmed differential expression of 23 microarray-selected genes in the entire benzene-exposed group, and 27 genes in the <1 ppm-exposed subgroup, compared with the control group. Using SL, we identified 3 pairs of genes that could predict <1 ppm benzene exposure with cross-validated AUC estimates >0.9 (p<0.0001) and were not predictive of other exposures (nickel, arsenic, smoking, stress). The predictive gene pairs are PRG2/CLEC5A, NFKBI/CLEC5A, and ACSL1/CLEC5A. They play roles in innate immunity and inflammatory responses. Using nCounter and SL, we validated the altered expression of multiple mRNAs by benzene and identified gene pairs predictive of exposure to benzene at levels below the US occupational standard of 1ppm.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
Competing Interests: G.L. has received funds from the American Petroleum Institute for consulting on benzene-related health research. S.M.R. has received consulting and expert testimony fees from law firms representing plaintiffs’ cases involving exposure to benzene and has received research support from the American Petroleum Institute and the American Chemistry Council. M.T.S. has received consulting and expert testimony fees from law firms representing both plaintiffs and defendants in cases involving exposure to benzene. The other authors declare that they have no actual or potential competing financial interests. This does not alter the authors’ adherence to PLOS ONE policies on sharing data and materials.
These authors also contributed equally to the work.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0205427