Selected techniques in diamond anvil cell crystallography: centring samples using X-ray transmission and rocking powder samples to improve X-ray diffraction image quality

The distinct X‐ray transmission profile obtained by scanning a sample in a diamond anvil cell across a collimated X‐ray beam is used to monitor sample displacement brought about by rotation. This measured displacement can in turn be used to calculate, and subsequently correct, the sample position wi...

Full description

Saved in:
Bibliographic Details
Published inJournal of synchrotron radiation Vol. 16; no. 1; pp. 83 - 96
Main Authors Smith, Jesse S., Desgreniers, Serge
Format Journal Article
LanguageEnglish
Published 5 Abbey Square, Chester, Cheshire CH1 2HU, England International Union of Crystallography 01.01.2009
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The distinct X‐ray transmission profile obtained by scanning a sample in a diamond anvil cell across a collimated X‐ray beam is used to monitor sample displacement brought about by rotation. This measured displacement can in turn be used to calculate, and subsequently correct, the sample position with respect to a centre of rotation. This centring method differs from others also based on transmission in that it does not require a 180° sample rotation, nor does it require prior positioning of the rotation axis in the path of the X‐ray beam. After a full description of the method, an example is presented together with an extended record of use to evaluate the method in a practical setting. The practice and benefits of rocking polycrystalline samples during X‐ray exposure have also been quantitatively examined. Changing the orientation of the sample grains with respect to the incident beam yields the expected result of a more homogeneous intensity distribution along Debye rings. Interestingly, by limiting the amount of time large grains assume a particular orientation, rocking brings about the added effect of significantly reducing detector saturation. Sample rocking yields more reliable relative intensities, a more appropriate line shape and narrower line width. Data are presented for a calibration standard at ambient pressure as well as a research sample at high pressure.
Bibliography:istex:0B665EF5CF8B57B8D2728C4ED73E8613269E6922
ark:/67375/WNG-LVND1998-4
ArticleID:JSYIE5024
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:1600-5775
0909-0495
1600-5775
DOI:10.1107/S0909049508030859