Performance of a new atrial fibrillation detection algorithm in a miniaturized insertable cardiac monitor: Results from the Reveal LINQ Usability Study

Background For clinicians, confidence in atrial fibrillation (AF) episode classification is an important consideration when electing to use insertable cardiac monitors (ICMs). Objective The purpose of this study was to report on the improved AF detection algorithm in the Reveal LINQ ICM. Methods The...

Full description

Saved in:
Bibliographic Details
Published inHeart rhythm Vol. 13; no. 7; pp. 1425 - 1430
Main Authors Sanders, Prashanthan, MBBS, PhD, FHRS, Pürerfellner, Helmut, MD, FHRS, Pokushalov, Evgeny, MD, Sarkar, Shantanu, PhD, Di Bacco, Marco, PharmD, Maus, Bärbel, PhD, Dekker, Lukas R.C., MD, PhD
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.07.2016
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background For clinicians, confidence in atrial fibrillation (AF) episode classification is an important consideration when electing to use insertable cardiac monitors (ICMs). Objective The purpose of this study was to report on the improved AF detection algorithm in the Reveal LINQ ICM. Methods The Reveal LINQ Usability Study is a nonrandomized, prospective, multicenter trial. The ICM has been miniaturized, uses wireless telemetry for remote patient monitoring, and its AF algorithm includes a new p-wave filter. At 1 month post-device insertion, Holter monitor data were collected and annotated for true AF episodes ≥2 minutes, and performance metrics were evaluated by comparing Holter annotations with ICM detections. Results The study enrolled 151 patients (age 56.6 ± 12.1, male 67%). Reasons for monitoring included AF ablation or AF management in 81.5% (n = 123), syncope in 12.6% (n = 19), and other indications in 5.9% (n = 9) of patients. Of the 138 patients with an analyzable Holter recording, a total of 112 true AF episodes were identified in 38 patients (27.5%). The overall accuracy of the ICM to detect durations of AF or non-AF episodes was 99.4%, and the AF burden measured by the ICM was highly correlated with the Holter (Pearson coefficient 0.995). Conclusion The new AF detection algorithm in the Reveal LINQ ICM accurately detects the presence or absence of AF. Additionally, it showed high sensitivity in detecting AF duration in patients with a history of intermittent and symptomatic AF.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1547-5271
1556-3871
DOI:10.1016/j.hrthm.2016.03.005