Verification of Abbott 25-OH-vitamin D assay on the architect system

Analytical and clinical verification of both old and new generations of the Abbott total 25-hydroxyvitamin D (25OHD) assays, and an examination of reference Intervals. Determination of between-run precision, and Deming comparison between patient sample results for 25OHD on the Abbott Architect, DiaS...

Full description

Saved in:
Bibliographic Details
Published inPractical laboratory medicine Vol. 7; pp. 27 - 35
Main Authors Hutchinson, Katrina, Healy, Martin, Crowley, Vivion, Louw, Michael, Rochev, Yury
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier B.V 01.04.2017
Elsevier
Online AccessGet full text

Cover

Loading…
More Information
Summary:Analytical and clinical verification of both old and new generations of the Abbott total 25-hydroxyvitamin D (25OHD) assays, and an examination of reference Intervals. Determination of between-run precision, and Deming comparison between patient sample results for 25OHD on the Abbott Architect, DiaSorin Liaison and AB SCIEX API 4000 (LC-MS/MS). Establishment of uncertainty of measurement for 25OHD Architect methods using old and new generations of the reagents, and estimation of reference interval in healthy Irish population. For between-run precision the manufacturer claims 2.8% coefficients of variation (CVs) of 2.8% and 4.6% for their high and low controls, respectively. Our instrument showed CVs between 4% and 6.2% for all levels of the controls on both generations of the Abbott reagents. The between-run uncertainties were 0.28 and 0.36, with expanded uncertainties 0.87 and 0.98 for the old and the new generations of reagent, respectively. The difference between all methods used for patients’ samples was within total allowable error, and the instruments produced clinically equivalent results. The results covered the medical decision points of 30, 40, 50 and 125nmol/L. The reference interval for total 25OHD in our healthy Irish subjects was lower than recommended levels (24–111 nmol/L). In a clinical laboratory Abbott 25OHD immunoassays are a useful, rapid and accurate method for measuring total 25OHD. The new generation of the assay was confirmed to be reliable, accurate, and a good indicator for 25OHD measurement. More study is needed to establish reference intervals that correctly represent the healthy population in Ireland. •A verification of the new version of the Abbott Architect 25OHD assay has been performed.•The prevalence of obesity in Ireland may be a contributing factor to low 25OHD levels.•Vitamin D (25OHD) testing can be important for general health screening.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2352-5517
2352-5517
DOI:10.1016/j.plabm.2017.01.001