Compressed sensing reconstruction improves sensitivity of variable density spiral fMRI
Purpose Functional MRI (fMRI) techniques that can provide excellent blood oxygen level dependent contrast, rapid whole brain imaging, and minimal spatial distortion are in demand. This study explored whether fMRI sensitivity can be improved through the use of compressed sensing (CS) reconstruction o...
Saved in:
Published in | Magnetic resonance in medicine Vol. 70; no. 6; pp. 1634 - 1643 |
---|---|
Main Authors | , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
Blackwell Publishing Ltd
01.12.2013
Wiley Subscription Services, Inc |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Purpose
Functional MRI (fMRI) techniques that can provide excellent blood oxygen level dependent contrast, rapid whole brain imaging, and minimal spatial distortion are in demand. This study explored whether fMRI sensitivity can be improved through the use of compressed sensing (CS) reconstruction of variable density spiral fMRI.
Methods
Three different CS‐reconstructed 1‐shot variable density spirals were explored (corresponding to 28%, 35%, and 46% under‐sampling), and compared with conventional 1‐shot and 2‐shot Archimedean spirals acquired using matched echo time and volume repetition time. fMRI maps were reconstructed with or without CS MRI and sensitivity was compared using identically matched voxels.
Results
The results demonstrated that an l1‐norm based CS reconstruction only led to an increase in functional contrast when applied to 28% under‐sampled data. A whole brain t‐contrast map revealed that 2‐shot uniformly sampled spiral and 28% under‐sampled spiral data reconstructed with CS yield equivalent sensitivity, even with matched echo time and volume repetition time
Conclusion
VD spiral exhibits a useful operating range, in the region of 25–30% under‐sampling, for which CS reconstruction can be used to increase the sensitivity of fMRI to brain activity. Using CS, VD acquisitions achieve the same sensitivity as 2‐shot Archimedean acquisitions, but require only a single shot. Magn Reson Med 70:1634–1643, 2013. © 2013 Wiley Periodicals, Inc. |
---|---|
Bibliography: | ark:/67375/WNG-JC87WWJ4-5 NSERC Discovery Program EPSRC - No. EP/F047991/1 Microsoft Research Connections istex:0C921596F3A2A3F1262B45DFCABBD5895CAF2B6C ArticleID:MRM24621 ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 ObjectType-Article-2 ObjectType-Feature-1 |
ISSN: | 0740-3194 1522-2594 |
DOI: | 10.1002/mrm.24621 |