Performance characteristics of scintigraphic measurement of gastric emptying of solids in healthy participants
Background Gastric emptying (GE) is measured in pharmacodynamic and diagnostic studies. Our aim was to assess inter‐ and intra‐subject coefficients of variation (COV) of scintigraphic GE measurements in healthy subjects, and associations of GE with gender and body mass index (BMI). Methods Data fr...
Saved in:
Published in | Neurogastroenterology and motility Vol. 24; no. 12; pp. 1076 - e562 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | English |
Published |
Oxford, UK
Blackwell Publishing Ltd
01.12.2012
Wiley Subscription Services, Inc |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Background Gastric emptying (GE) is measured in pharmacodynamic and diagnostic studies. Our aim was to assess inter‐ and intra‐subject coefficients of variation (COV) of scintigraphic GE measurements in healthy subjects, and associations of GE with gender and body mass index (BMI).
Methods Data from participants with scintigraphic measurements of gastric emptying of solids were analyzed. Primary endpoints were gastric emptying T1/2 (GE T1/2) and GE at 1, 2, 3, and 4 h.
Key Results The patient cohort consisted of 105 males and 214 females; at least two studies were performed in 47 subjects [16 males (M), 32 females (F)]. Inter‐subject COV (COVinter) for GE T1/2 were similar in M and F: overall 24.5% (M 26.0%, F 22.5%); COV are predictably lowest for GE at 4 h (COVinter 9.6%). COVintra for T1/2 and GE at 4 h were overall 23.8% and 12.6%, and were similar to COVinter values. Gender (but not age or BMI) was significantly associated with GE T1/2 [P < 0.001, F 127.6 ± 28.7 (SD) min; M 109.9 ± 28.6 min] and with GE at 1 h and 2 h. Repeat GE T1/2 values in 47 participants were significantly correlated (r = 0.459, P < 0.001) with median difference of −6 min (mean −1.6, range −56 to 72 min). Bland–Altman plots showed Δ GE T1/2 similarly distributed across mean GE T1/2 100–155 min, and across studies conducted 90–600 days apart.
Conclusions & Inferences Inter‐subject variations in scintigraphic GE results are only slightly higher than the intra‐subject measurements, which are also reproducible over time in healthy volunteers. Gender, but not BMI, is significantly associated with GE results. |
---|---|
Bibliography: | ark:/67375/WNG-C2JQLLNH-C istex:292706060AC18C9F701386076FA5D7C6238D94C8 ArticleID:NMO1972 ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 ObjectType-Article-2 ObjectType-Feature-1 |
ISSN: | 1350-1925 1365-2982 1365-2982 |
DOI: | 10.1111/j.1365-2982.2012.01972.x |