Comparison between technetium-99m methoxyisobutylisonitrile scintigraphy and ultrasound in the diagnosis of parathyroid adenoma and parathyroid hyperplasia
The aim of this study was to evaluate the value of technetium-99m methoxyisobutylisonitrile (Tc-MIBI) imaging and ultrasound in preoperative localization of parathyroid adenoma (PA) and parathyroid hyperplasia (PH). A retrospective study of Tc-MIBI double-phase scintigraphy (DPS) was performed in 18...
Saved in:
Published in | Nuclear medicine communications Vol. 39; no. 12; p. 1129 |
---|---|
Main Authors | , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
England
01.12.2018
|
Subjects | |
Online Access | Get more information |
Cover
Loading…
Summary: | The aim of this study was to evaluate the value of technetium-99m methoxyisobutylisonitrile (Tc-MIBI) imaging and ultrasound in preoperative localization of parathyroid adenoma (PA) and parathyroid hyperplasia (PH).
A retrospective study of Tc-MIBI double-phase scintigraphy (DPS) was performed in 187 hyperparathyroidism cases with pathologically diagnosed PA or PH. Of these patients, 167 cases underwent ultrasound, and 146 cases underwent Tc-MIBI single-photon emission computed tomography/computed tomography (SPECT/CT). The sensitivity and diagnostic accuracy of ultrasound, Tc-MIBI DPS, and SPECT/CT were compared between PA and PH. Differences in Tc-MIBI DPS, serum parathyroid hormone (PTH), serum calcium and phosphorus, as well as the weight and longest diameter of lesion between PA and PH were also compared.
As per patient-based analysis, the sensitivity of ultrasound, Tc-MIBI DPS, and SPECT/CT was 90.70% (39/43), 95.56% (43/45), and 100.00% (30/30), respectively, for PA, and 93.55% (116/124), 90.85% (129/142), and 93.10% (108/116), respectively, for PH. There were no significant differences in sensitivity of these three imaging methods between PA and PH. However, per lesion-based analysis, the accuracy of ultrasound, Tc-MIBI DPS, and SPECT/CT in detecting PA was 78.43% (40/51), 86.79% (46/53) and 96.88% (31/32), respectively, and the accuracy of Tc-MIBI DPS was higher than that of ultrasound (χ=6.507, P=0.011), and for PH, it was 49.69% (160/322), 40.71% (171/420), and 43.80% (152/347), respectively. The accuracy of ultrasound was higher than that of Tc-MIBI DPS (χ=5.940, P=0.015). The accuracy of a combination of all three examinations of ultrasound+Tc-MIBI DPS, ultrasound+Tc-MIBI SPECT/CT, Tc-MIBI DPS+SPECT/CT, and ultrasound+Tc-MIBI DPS+Tc-MIBI SPECT/CT was 51.51% (154/299), 53.85% (161/299), 50.17% (150/299), and 54.18% (162/299), respectively, which was higher than that of ultrasound (χ=5.273, P=0.022; χ=8.226, P=0.004; χ=3.880, P=0.049; χ=8.702, P=0.003, respectively). Serum levels of PTH and phosphorus were lower in patients with PA than in patients with PH (P<0.001), and serum calcium level, the weight, and the longest diameter of lesion and early uptake rate of Tc-MIBI DPS were higher in patients with PA than in patients with PH (P<0.01). Serum PTH level is often less than 1000 pg/ml in PA, but usually more than 1000 pg/ml in PH.
Ultrasound, Tc-MIBI DPS, and SPECT/CT all have a higher value in the diagnosis of PA than PH. Tc-MIBI SPECT/CT should be optimal for detecting PA, and early SPECT/CT scan might be better than delayed scan. Compared with Tc-MIBI DPS and SPECT/CT, ultrasound has a slight advantage in localization of PH lesions. The combination of ultrasound and Tc-MIBI DPS or SPECT/CT imaging could improve the accuracy in localization of PH lesions and should be considered as the first-line method for detecting PH. |
---|---|
ISSN: | 1473-5628 |
DOI: | 10.1097/MNM.0000000000000921 |