Effects of ultrasound guidance on the minimum effective anaesthetic volume required to block the femoral nerve

We tested the hypothesis that ultrasound guidance may reduce the minimum effective anaesthetic volume (MEAV50) of ropivacaine 0.5% required to block the femoral nerve compared with nerve stimulation guidance. After standard premedication and sciatic nerve block were given, 60 patients undergoing kne...

Full description

Saved in:
Bibliographic Details
Published inBritish journal of anaesthesia : BJA Vol. 98; no. 6; pp. 823 - 827
Main Authors Casati, A., Baciarello, M., Cianni, S. Di, Danelli, G., De Marco, G., Leone, S., Rossi, M., Fanelli, G.
Format Journal Article
LanguageEnglish
Published Oxford Elsevier Ltd 01.06.2007
Oxford University Press
Oxford Publishing Limited (England)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:We tested the hypothesis that ultrasound guidance may reduce the minimum effective anaesthetic volume (MEAV50) of ropivacaine 0.5% required to block the femoral nerve compared with nerve stimulation guidance. After standard premedication and sciatic nerve block were given, 60 patients undergoing knee arthroscopy were randomly allocated to receive a femoral nerve block with ropivacaine 0.5% using either nerve stimulation (group NS, n = 30) or ultrasound (group US, n = 30) guidance. The volume of the injected solution was varied for consecutive patients based on an up-and-down staircase method according to the response of the previous patient. The initial volume was 12 ml. A double-blinded observer evaluated the occurrence of complete loss of pinprick sensation in the femoral nerve distribution, with concomitant block of the quadriceps muscle: positive or negative responses within 30 min after the injection determined a 3 ml decrease or increase for the next patient, respectively. The mean (sd) MEAV50 for femoral nerve block was 15 (4) ml (95% CI, 7–23 ml) in group US and 26 (4) ml (95% CI, 19–33 ml) in group NS (P = 0.002). The effective dose in 95% of cases (ED95) calculated with probit transformation and logistic regression analysis was 22 ml (95% CI, 13–36 ml) in group US, and 41 ml (95% CI, fs 24–66 ml) in group NS. Ultrasound guidance provided a 42% reduction in the MEAV of ropivacaine 0.5% required to block the femoral nerve as compared with the nerve stimulation guidance.
Bibliography:ArticleID:aem100
Dr Casati sadly died in a tragic accident in April, 2007. The other authors of this article would like to acknowledge the fact that he was a great man and an internationally acclaimed regional anesthesiologist.
istex:96B087C6E2D44011CA5697CB5345B882FF8A4691
ark:/67375/HXZ-LDLM7VGN-F
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Article-2
ObjectType-News-1
ObjectType-Feature-3
ISSN:0007-0912
1471-6771
DOI:10.1093/bja/aem100