Evaluating Self-Healing Behaviour of Asphalt Binders Modified with Phase-Change Materials, Polymers and Recycled Glass Powder

The objective of this paper is to evaluate the fatigue resistance and self-healing properties of asphalt binders modified with different types of additives (Styrene-Butadiene-Styrene (SBS), Glass Powder (GP) and Phase-Change Materials blended with Glass Powder (GPCM)). Two base binders were used in...

Full description

Saved in:
Bibliographic Details
Published inPolymers Vol. 15; no. 8; p. 1934
Main Authors Almutairi, Haya, Baaj, Hassan
Format Journal Article
LanguageEnglish
Published Switzerland MDPI AG 19.04.2023
MDPI
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The objective of this paper is to evaluate the fatigue resistance and self-healing properties of asphalt binders modified with different types of additives (Styrene-Butadiene-Styrene (SBS), Glass Powder (GP) and Phase-Change Materials blended with Glass Powder (GPCM)). Two base binders were used in this study: a PG 58-28 straight-run asphalt binder and a PG 70-28 Polymer modified with 3%SBS. Moreover, the GP was added to the two base binders at two different percentages of 3.5% and 5% by binder weight. However, the GPCM was added with two different percentages of 5% and 7% by binder weight. In this paper, the fatigue resistance and self-healing properties were evaluated using Linear Amplitude Sweep (LAS) test. Two different procedures were adopted. In the first procedure, the load was applied continuously until failure (without a rest period), whereas, in the second procedure, rest periods of 5 and 30 min were introduced. The obtained results of the experimental campaign were ranked based on three different categories: Linear Amplitude Sweep (LAS), Pure Linear Amplitude Sweep (PLAS) and modified Pure Linear Amplitude Sweep (PLASH). The addition of GPCM appears to positively impact the fatigue performance of both straight-run and polymer-modified asphalt binders. Furthermore, when a short rest period of 5 min was introduced, the use of GPCM did not appear to improve the healing potential. However, a better healing capacity was observed when the 30 min rest period was applied. Moreover, the addition of GP alone to the base binder was not beneficial in improving fatigue performance based on LAS and PLAS methods. However, there was a slight reduction in the fatigue performance based on the PLAS method. Finally, unlike the PG 58-28, the healing capacity of the GP 70-28 was negatively affected by the addition of the GP.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2073-4360
2073-4360
DOI:10.3390/polym15081934