Over-the-wire deployment techniques of option elite inferior vena cava filter: 3D printing vena cava phantom study

•Bent stiff-wire technique with transfemoral access had lower filter tilt ratio at Option IVC filter deployment.•Original push wire with transjugular access had lower filter tilt ratio at Option IVC filter deployment.•Filter jumping was common using the original push wire with transjugular access. T...

Full description

Saved in:
Bibliographic Details
Published inEuropean journal of radiology Open Vol. 7; p. 100227
Main Authors Park, Byung Geon, Seo, Anna, Lee, Sang Yub, Cha, Jung Guen, Hong, Jihoon, Lee, Hoseok, Heo, Jun, Do, Young Woo
Format Journal Article
LanguageEnglish
Published England Elsevier Ltd 01.01.2020
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:•Bent stiff-wire technique with transfemoral access had lower filter tilt ratio at Option IVC filter deployment.•Original push wire with transjugular access had lower filter tilt ratio at Option IVC filter deployment.•Filter jumping was common using the original push wire with transjugular access. To compare filter tilt and filter jumping during Option inferior vena cava (IVC) filter deployment with 3 different wires techniques using a 3-dimensional (3D) printing vena cava phantom. An IVC 3D printed vena cava phantom was made from a healthy young male’s computed tomographic data. Option IVC filters were deployed with 3 different wires: i) original push wire, ii) hydrophilic stiff wire, and iii) bent stiff wire. Right internal jugular and right femoral access were used 5 times with each wire. Filter tilt angle, tilt ratio, jumping, and tip abutment to the IVC wall were analyzed. The transfemoral approach with original push wire had significantly higher tilt angle than did the transjugular approach (6.1˚ ± 1.9 vs. 3.5˚ ± 1.3, p = 0.04). Mean tilt ratio was significantly lower with the bent wire with transfemoral access (0.49 ± 0.13 vs. 0.78 ± 0.18 [original push-wire] and 0.67 ± 0.08 [stiff wire], p = 0.019). The ratio was lower also with original push wire with transjugular access (0.34 ± 0.19 vs. 0.57 ±0.11 [stiff wire] and 0.58 ±0.17 [bent wire], p = 0.045). Filter jumping occurred more often with the transjugular approach with original push wire than with stiff or bent-wire delivery. Filter tip abutment to the IVC wall occurred only with the transfemoral approach. Bent wire with transfemoral access and original push wire with transjugular access had lower filter tilt ratio at Option IVC filter deployment. However, filter jumping was common using the original push wire with transjugular access.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
These authors contributed equally in this study.
ISSN:2352-0477
2352-0477
DOI:10.1016/j.ejro.2020.100227