Ultrasound-guided infraclavicular brachial plexus block

Peripheral nerve blocks are almost always performed as blind procedures. The purpose of this study was to test the feasibility of seeing individual nerves of the brachial plexus and directing the block needle to these nerves with real time imaging. Using ultrasound guidance, infraclavicular brachial...

Full description

Saved in:
Bibliographic Details
Published inBritish journal of anaesthesia : BJA Vol. 89; no. 2; pp. 254 - 259
Main Authors Sandhu, N.S., Capan, L.M.
Format Journal Article
LanguageEnglish
Published Oxford Elsevier Ltd 01.08.2002
Oxford University Press
Oxford Publishing Limited (England)
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Peripheral nerve blocks are almost always performed as blind procedures. The purpose of this study was to test the feasibility of seeing individual nerves of the brachial plexus and directing the block needle to these nerves with real time imaging. Using ultrasound guidance, infraclavicular brachial plexus block was performed in 126 patients. Important aspects of this standardized technique included (i) imaging the axillary artery and the three cords of the brachial plexus posterior to the pectoralis minor muscle, (ii) marking the position of the ultrasound probe before introducing a Tuohy needle, (iii) maintaining the image of the entire length of the needle at all times during its advancement, (iv) depositing local anaesthetic around each of the three cords and (v) placing a catheter anterior to the posterior cord when indicated. In 114 (90.4%) patients, an excellent block permitted surgery without a need for any supplemental anaesthetic or conversion to general anaesthesia. In nine (7.2%) patients local or perineural administration of local anaesthetic, and in three (2.4%) conversion to general anaesthesia, was required. Mean times to administer the block, onset of block and complete block were 10.0 (sd 4.4), 3.0 (1.3) and 6.7 (3.2) min, respectively. Mean lidocaine dose was 695 (107) mg. In one patient, vascular puncture occurred. In 53 (42.6%) patients, an indwelling catheter was placed, but only three required repeat injections, which successfully prolonged the block. The use of ultrasound appears to permit accurate deposition of the local anaesthetic perineurally, and has the potential to improve the success and decrease the complications of infraclavicular brachial plexus block.
Bibliography:local:aef186
Accepted for publication: March 6, 2002
istex:FEE38BFA41D0B5A43BFEF8320A77FF53EAE49313
ark:/67375/HXZ-FMX4BRFH-N
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0007-0912
1471-6771
DOI:10.1093/bja/aef186