Improved Electrochemical Hydrogen Peroxide Detection Using a Nickel(II) Phthalimide-Substituted Porphyrazine Combined with Various Carbon Nanomaterials

A metal-free porphyrazine derivative with peripheral phthalimide substituents was metallated with a nickel(II) ion. The purity of the nickel macrocycle was confirmed using HPLC, and characterized by MS, UV-VIS, and 1D ( H, C) and 2D ( H- C HSQC, H- C HMBC, H- H COSY) NMR techniques. The novel porphy...

Full description

Saved in:
Bibliographic Details
Published inNanomaterials (Basel, Switzerland) Vol. 13; no. 5; p. 862
Main Authors Leda, Amanda, Hassani, Mina, Rebis, Tomasz, Falkowski, Michal, Piskorz, Jaroslaw, Mlynarczyk, Dariusz T, McNeice, Peter, Milczarek, Grzegorz
Format Journal Article
LanguageEnglish
Published Switzerland MDPI AG 25.02.2023
MDPI
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A metal-free porphyrazine derivative with peripheral phthalimide substituents was metallated with a nickel(II) ion. The purity of the nickel macrocycle was confirmed using HPLC, and characterized by MS, UV-VIS, and 1D ( H, C) and 2D ( H- C HSQC, H- C HMBC, H- H COSY) NMR techniques. The novel porphyrazine was combined with various carbon nanomaterials, such as carbon nanotubes-single walled (SWCNTs) and multi-walled (MWCNTs), and electrochemically reduced graphene oxide (rGO), to create hybrid electroactive electrode materials. The carbon nanomaterials' effect on the electrocatalytic properties of nickel(II) cations was compared. As a result, an extensive electrochemical characterization of the synthesized metallated porphyrazine derivative on various carbon nanostructures was carried out using cyclic voltammetry (CV), chronoamperometry (CA), and electrochemical impedance spectroscopy (EIS). An electrode modified with carbon nanomaterials GC/MWCNTs, GC/SWCNTs, or GC/rGO, respectively, was shown to have a lower overpotential than a bare glassy carbon electrode (GC), allowing for the measurement of hydrogen peroxide in neutral conditions (pH 7.4). It was shown that among the tested carbon nanomaterials, the modified electrode GC/MWCNTs/ exhibited the best electrocatalytic properties in the direction of hydrogen peroxide oxidation/reduction. The prepared sensor was determined to enable a linear response to H O in concentrations ranging between 20-1200 µM with the detection limit of 18.57 µM and sensitivity of 14.18 µA mM cm . As a result of this research, the sensors produced here may find use in biomedical and environmental applications.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2079-4991
2079-4991
DOI:10.3390/nano13050862