HDL cholesterol performance using an ultracentrifugation reference measurement procedure and the designated comparison method
Accurate high-density lipoprotein cholesterol (HDL-C) measurements are important for management of cardiovascular diseases. The US Centers for Disease Control and Prevention (CDC) and Cholesterol Reference Method Laboratory Network (CRMLN) perform ultracentrifugation (UC) reference measurement proce...
Saved in:
Published in | Clinica chimica acta Vol. 439; pp. 185 - 190 |
---|---|
Main Authors | , , , , , , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Netherlands
Elsevier B.V
15.01.2015
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Accurate high-density lipoprotein cholesterol (HDL-C) measurements are important for management of cardiovascular diseases. The US Centers for Disease Control and Prevention (CDC) and Cholesterol Reference Method Laboratory Network (CRMLN) perform ultracentrifugation (UC) reference measurement procedure (RMP) to value assign HDL-C. Japanese CRMLN laboratory (Osaka) concurrently runs UC procedure and the designated comparison method (DCM). Osaka performance of UC and DCM was examined and compared with CDC RMP.
CDC RMP involved UC, heparin-MnCl2 precipitation, and cholesterol analysis. CRMLN DCM for samples containing <200mg/dl triglycerides involved 50-kDa dextran sulfate-MgCl2 precipitation and cholesterol determination.
HDL-C regression equations obtained with CDC (x) and Osaka (y) were y=0.992x+0.542 (R2=0.996) for Osaka UC and y=1.004x−0.181 (R2=0.998) for DCM. Pass rates within ±1mg/dl of the CDC target value were 91.9 and 92.1% for Osaka UC and DCM, respectively. Biases at 40mg/dl HDL-C were +0.22 and −0.02mg/dl for Osaka UC and DCM, respectively.
Osaka UC and DCM were highly accurate, precise, and stable for many years, assisting manufacturers to calibrate products for clinical laboratories to accurately measure HDL-C for patients, calculate non-HDL-C, and estimate low-density lipoprotein cholesterol with the Friedewald equation.
•CDC ultracentrifugation method is the reference measurement procedure of HDL-C.•We used both ultracentrifugation and designated comparison methods for HDL-C.•We participated in the CDC HDL-C standardization program.•We aimed to clarify the precision and accuracy of both methods for HDL-C at Osaka.•Both methods showed to be accurate, precise and stable for over 17years. |
---|---|
ISSN: | 0009-8981 1873-3492 |
DOI: | 10.1016/j.cca.2014.10.039 |