Detecting temporal lobe seizures in ultra long-term subcutaneous EEG using algorithm-based data reduction

•Ultra long-term subcutaneous EEG offers a novel option for the recording of electrographic epileptic seizures in everyday life.•A semi-automatic seizure detection process is proposed to limit the time spent on review to periods of potential seizure activity.•The algorithm of the semi-automatic dete...

Full description

Saved in:
Bibliographic Details
Published inClinical neurophysiology Vol. 142; pp. 86 - 93
Main Authors Remvig, Line S., Duun-Henriksen, Jonas, Fürbass, Franz, Hartmann, Manfred, Viana, Pedro F., Kappel Overby, Anne Mette, Weisdorf, Sigge, Richardson, Mark P., Beniczky, Sándor, Kjaer, Troels W.
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier B.V 01.10.2022
Subjects
Online AccessGet full text
ISSN1388-2457
1872-8952
1872-8952
DOI10.1016/j.clinph.2022.07.504

Cover

Loading…
More Information
Summary:•Ultra long-term subcutaneous EEG offers a novel option for the recording of electrographic epileptic seizures in everyday life.•A semi-automatic seizure detection process is proposed to limit the time spent on review to periods of potential seizure activity.•The algorithm of the semi-automatic detection process had a sensitivity of 86% and a false detection rate of 2.4 per 24 hours. Ultra long-term monitoring with subcutaneous EEG (sqEEG) offers objective outpatient recording of electrographic seizures as an alternative to self-reported epileptic seizure diaries. This methodology requires an algorithm-based automatic seizure detection to indicate periods of potential seizure activity to reduce the time spent on visual review. The objective of this study was to evaluate the performance of a sqEEG-based automatic seizure detection algorithm. A multicenter cohort of subjects using sqEEG were analyzed, including nine people with epilepsy (PWE) and 12 healthy subjects, recording a total of 965 days. The automatic seizure detections of a deep-neural-network algorithm were compared to annotations from three human experts. Data reduction ratios were 99.6% in PWE and 99.9% in the control group. The cross-PWE sensitivity was 86% (median 80%, range 69–100% when PWE were evaluated individually), and the corresponding median false detection rate was 2.4 detections per 24 hours (range: 2.0–13.0). Our findings demonstrated that step one in a sqEEG-based semi-automatic seizure detection/review process can be performed with high sensitivity and clinically applicable specificity. Ultra long-term sqEEG bears the potential of improving objective seizure quantification.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1388-2457
1872-8952
1872-8952
DOI:10.1016/j.clinph.2022.07.504