Practical issues regarding angular and energy response in in vivo intraoperative electron radiotherapy dosimetry

Abstract Aim To estimate angular response deviation of MOSFETs in the realm of intraoperative electron radiotherapy (IOERT), review their energy dependence, and propose unambiguous names for detector rotations. Background MOSFETs have been used in IOERT. Movement of the detector, namely rotations, c...

Full description

Saved in:
Bibliographic Details
Published inReports of practical oncology and radiotherapy Vol. 22; no. 1; pp. 55 - 67
Main Authors López-Tarjuelo, Juan, Bouché-Babiloni, Ana, Morillo-Macías, Virginia, Santos-Serra, Agustín, Ferrer-Albiach, Carlos
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier Urban & Partner Sp. z o.o 01.01.2017
Elsevier
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract Aim To estimate angular response deviation of MOSFETs in the realm of intraoperative electron radiotherapy (IOERT), review their energy dependence, and propose unambiguous names for detector rotations. Background MOSFETs have been used in IOERT. Movement of the detector, namely rotations, can spoil results. Materials and methods We propose yaw, pitch, and roll to name the three possible rotations in space, as these unequivocally name aircraft rotations. Reinforced mobile MOSFETs (model TN-502RDM-H) and an Elekta Precise linear accelerator were used. Two detectors were placed in air for the angular response study and the whole set of five detectors was calibrated as usual to evaluate energy dependence. Results The maximum readout was obtained with a roll of 90° and 4 MeV. With regard to pitch movement, a substantial drop in readout was achieved at 90°. Significant overresponse was measured at 315° with 4 MeV and at 45° with 15 MeV. Energy response is not different for the following groups of energies: 4, 6, and 9 MeV; and 12 MeV, 15 MeV, and 18 MeV. Conclusions Our proposal to name MOSFET rotations solves the problem of defining sensor orientations. Angular response could explain lower than expected results when the tip of the detector is lifted due to inadvertent movements. MOSFETs energy response is independent of several energies and differs by a maximum of 3.4% when dependent. This can limit dosimetry errors and makes it possible to calibrate the detectors only once for each group of energies, which saves time and optimizes lifespan of MOSFETs.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1507-1367
2083-4640