Electromagnetic stereotactic navigation for external ventricular drain placement in the intensive care unit

Abstract Placement of external ventricular drains subjects patients to risks of injury, intracerebral hematoma, and failure from improper placement. Traditional free-hand placement has been associated with a relatively frequent occurrence of these complications. We sought to assess the accuracy of v...

Full description

Saved in:
Bibliographic Details
Published inJournal of clinical neuroscience Vol. 20; no. 12; pp. 1718 - 1722
Main Authors Mahan, Mark, Spetzler, Robert F, Nakaji, Peter
Format Journal Article
LanguageEnglish
Published Scotland Elsevier Ltd 01.12.2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Abstract Placement of external ventricular drains subjects patients to risks of injury, intracerebral hematoma, and failure from improper placement. Traditional free-hand placement has been associated with a relatively frequent occurrence of these complications. We sought to assess the accuracy of ventriculostomy when performed using image-navigation technology in the intensive care unit (ICU). Thirty-five patients were consecutively enrolled in a single-arm trial evaluating the accuracy and complications from ventriculostomies performed at the ICU bedside using electromagnetic image guidance technology. The duration of any additional imaging and the length of the total procedure were also quantified. There were no unacceptably placed ventriculostomy catheters; only two catheters were not perfectly placed in the ipsilateral frontal horn. There was only one patient with tract hemorrhage. The use of image guidance technology added approximately 36 minutes to the time from when the need was identified to when successful drainage was achieved ( p = 0.002), but added only 4 minutes of operative time ( p = 0.12). Accuracy of placement demonstrated a statistically significant improvement in the accuracy of ventriculostomy over historical data. There were two registration failures which were converted to the traditional technique; there were no other complications arising from the use of image-guided technology. Electromagnetic image guidance is feasible and accurate. Image guidance technology eliminated unacceptably placed catheters and may reduce the risk of catheter-associated intracerebral hemorrhages.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Article-2
ObjectType-Feature-1
ISSN:0967-5868
1532-2653
DOI:10.1016/j.jocn.2013.03.005