Echocardiographic Methods, Quality Review, and Measurement Accuracy in a Randomized Multicenter Clinical Trial of Marfan Syndrome

Background The Pediatric Heart Network is conducting a large international randomized trial to compare aortic root growth and other cardiovascular outcomes in 608 subjects with Marfan syndrome randomized to receive atenolol or losartan for 3 years. The authors report here the echocardiographic metho...

Full description

Saved in:
Bibliographic Details
Published inJournal of the American Society of Echocardiography Vol. 26; no. 6; pp. 657 - 666
Main Authors Selamet Tierney, Elif Seda, MD, Levine, Jami C., MD, Chen, Shan, MS, Bradley, Timothy J., MBChB, Pearson, Gail D., MD, ScD, Colan, Steven D., MD, Sleeper, Lynn A., ScD, Campbell, M. Jay, MD, Cohen, Meryl S., MD, De Backer, Julie, MD, PhD, Guey, Lin T., PhD, Heydarian, Haleh, MD, Lai, Wyman W., MD, MPH, Lewin, Mark B., MD, Marcus, Edward, SM, Mart, Christopher R., MD, Pignatelli, Ricardo H., MD, Printz, Beth F., MD, PhD, Sharkey, Angela M., MD, Shirali, Girish S., MD, Srivastava, Shubhika, MBBS, Lacro, Ronald V., MD
Format Journal Article
LanguageEnglish
Published United States Mosby, Inc 01.06.2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background The Pediatric Heart Network is conducting a large international randomized trial to compare aortic root growth and other cardiovascular outcomes in 608 subjects with Marfan syndrome randomized to receive atenolol or losartan for 3 years. The authors report here the echocardiographic methods and baseline echocardiographic characteristics of the randomized subjects, describe the interobserver agreement of aortic measurements, and identify factors influencing agreement. Methods Individuals aged 6 months to 25 years who met the original Ghent criteria and had body surface area–adjusted maximum aortic root diameter (ROOTmax ) Z scores > 3 were eligible for inclusion. The primary outcome measure for the trial is the change over time in ROOTmax Z score. A detailed echocardiographic protocol was established and implemented across 22 centers, with an extensive training and quality review process. Results Interobserver agreement for the aortic measurements was excellent, with intraclass correlation coefficients ranging from 0.921 to 0.989. Lower interobserver percentage error in ROOTmax measurements was independently associated (model R2  = 0.15) with better image quality ( P  = .002) and later study reading date ( P < .001). Echocardiographic characteristics of the randomized subjects did not differ by treatment arm. Subjects with ROOTmax Z scores ≥ 4.5 (36%) were more likely to have mitral valve prolapse and dilation of the main pulmonary artery and left ventricle, but there were no differences in aortic regurgitation, aortic stiffness indices, mitral regurgitation, or left ventricular function compared with subjects with ROOTmax Z  scores < 4.5. Conclusions The echocardiographic methodology, training, and quality review process resulted in a robust evaluation of aortic root dimensions, with excellent reproducibility.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-3
content type line 23
ObjectType-Review-2
ISSN:0894-7317
1097-6795