Is a Single Respiratory Correlated 4D-CT Study Sufficient for Evaluation of Breathing Motion?
Purpose: Respiratory correlated computed tomography has been shown to be effective for evaluation of breathing-induced motion of pulmonary tumors. This study investigated whether a single four-dimensional CT study (4D-CT) is representative and sufficient for treatment planning in stereotactic body r...
Saved in:
Published in | International journal of radiation oncology, biology, physics Vol. 67; no. 5; pp. 1352 - 1359 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
Elsevier Inc
01.04.2007
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Purpose: Respiratory correlated computed tomography has been shown to be effective for evaluation of breathing-induced motion of pulmonary tumors. This study investigated whether a single four-dimensional CT study (4D-CT) is representative and sufficient for treatment planning in stereotactic body radiotherapy (SBRT). Methods and Materials: Four repeated helical 4D-CT studies were acquired every 10 min for 10 patients with 14 pulmonary metastases. Patients remained immobilized in a stereotactic body frame (SBF) for 30 min; abdominal compression was applied to seven patients. Using amplitude based sorting, eight phases equally distributed over the breathing cycle were reconstructed for each 4D-CT study. Tumor position was defined in a total of 406 CT series and variability of breathing motion and mean tumor position were evaluated. Results: Peak-to-peak tumor motion was 9.9 mm ± 6.8 mm (mean ± standard deviation) and 9.0 mm ± 7.4 mm at time point 0 min (t0 ) and t30 , respectively. In one patient with poor pulmonary function, continuous increase of breathing motion from 17.4 mm at t0 to 28.3 mm at t30 was seen. In five and two lesions, respectively, a drift of the mean tumor position greater than 3 mm and 5 mm was observed. A borderline significance was calculated for larger tumor position variability in midventilation phases compared with peak-ventilation phases of the breathing cycle ( p = 0.08). Conclusion: Treatment planning based on a single 4D-CT study is reliable for the majority of patients. Increased intrafractional uncertainties were seen for patients with poor pulmonary function and with tumors located in the lower lobe. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0360-3016 1879-355X |
DOI: | 10.1016/j.ijrobp.2006.11.025 |