On-line coupling of SPE and CE-MS for peptide analysis

An on‐line SPE‐CE‐MS system has been developed for the analysis of peptides. Analytes are preconcentrated using a C18 microcolumn (5×0.5 mm id), and then introduced into the CE system via a valve interface. The CE system with a Polybrene‐poly(vinylsulfonate) bilayer coated capillary is combined with...

Full description

Saved in:
Bibliographic Details
Published inElectrophoresis Vol. 28; no. 9; pp. 1319 - 1326
Main Authors Tempels, F. W. Alexander, Underberg, Willy J. M., Somsen, Govert W., de Jong, Gerhardus J.
Format Journal Article
LanguageEnglish
Published Weinheim WILEY-VCH Verlag 01.05.2007
WILEY‐VCH Verlag
Subjects
Online AccessGet full text
ISSN0173-0835
1522-2683
DOI10.1002/elps.200600403

Cover

Loading…
More Information
Summary:An on‐line SPE‐CE‐MS system has been developed for the analysis of peptides. Analytes are preconcentrated using a C18 microcolumn (5×0.5 mm id), and then introduced into the CE system via a valve interface. The CE system with a Polybrene‐poly(vinylsulfonate) bilayer coated capillary is combined with an ion‐trap mass spectrometer via ESI using a coaxial sheath‐liquid sprayer. The on‐line coupling of the SPE and CE step by the valve interface is advantageous because it allows an independent functioning of the system parts. Optimization of the SPE‐CE system was performed using UV detection. Subsequently, the SPE‐CE system has been coupled to the ion‐trap mass spectrometer. Test solutions with enkephalin peptides (50 ng/mL) were used for evaluation of system performance. Repeatability of effective mobility and peak area ratio of the two enkephalins were within 1.2% and 9% RSD, respectively. The analysis of 1:1 v/v diluted cerebrospinal fluid samples spiked with enkephalin peptides showed detection limits (S/N = 3) in the range of 1.5–3 ng/mL (around 5 nM), which were similar to those obtained for enkephalin test solutions. Moreover, the potential of the on‐line SPE‐CE‐MS system was demonstrated by the analysis of a cytochrome C digest. Some hydrophilic peptides did not show sufficient retention on the SPE column, and were lost during preconcentration. Nonetheless, positive identification of the protein was achieved, indicating the feasibility of the system for proteomics.
Bibliography:ArticleID:ELPS200600403
istex:83128C987EE9AE514EACFD195DA7F3A8CFB999F6
ark:/67375/WNG-XH8F5SQ9-7
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:0173-0835
1522-2683
DOI:10.1002/elps.200600403