Fractional volume of placental vessels in women with diabetes using a novel stereological 3D power Doppler technique
In maternal diabetes the placenta is large with abnormal vascular development and increased villous volume. We used a novel stereological 3D power Doppler ultrasound technique to investigate differences in-vivo in the placental fractional volume of power Doppler signal (FrVol-PD) between women with...
Saved in:
Published in | Placenta (Eastbourne) Vol. 34; no. 11; pp. 1002 - 1008 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
Kidlington
Elsevier Ltd
01.11.2013
Elsevier |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | In maternal diabetes the placenta is large with abnormal vascular development and increased villous volume. We used a novel stereological 3D power Doppler ultrasound technique to investigate differences in-vivo in the placental fractional volume of power Doppler signal (FrVol-PD) between women with and without diabetes.
We recruited 17 pregnant women with pre-gestational diabetes and 20 controls, all with anterior placentae. Each subject had ultrasound scans (Voluson 730 Expert) every 4 weeks between 12 and 32 weeks gestation. 3D power Doppler data were acquired and the placenta manually outlined using VOCAL (4D View). Power Doppler signal within the resultant volume was counted in a 3D manner adapting the random but systematic techniques used in stereology.
Subjects were of similar age, BMI and parity. From 16 weeks the mean (SD) placental FrVol-PD was higher in the non-diabetic than in the diabetic group: 16 weeks – 0.125 (0.03) versus 0.108 (0.03), 20 weeks – 0.144 (0.05) versus 0.104 (0.03), 24 weeks – 0.145 (0.05) versus 0.128 (0.03), 28 weeks – 0.159 (0.05) versus 0.133 (0.02) and 32 weeks – 0.154 (0.03) versus 0.123 (0.04). These differences were significant between control and diabetic subjects [F(1,35) = 4.737, p = 0.036] and across gestation [F(3,140) = 8.294, p < 0.001].
Using a novel stereological-based ultrasound technique we have demonstrated the reliability of this application in the placenta. This technique shows promise for non-invasive assessment of placental function: further studies are required to identify if structural changes in a diabetic placenta are accompanied by altered function, manifest as reduced perfusion demonstrable in-vivo. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 ObjectType-Undefined-3 |
ISSN: | 0143-4004 1532-3102 1532-3102 |
DOI: | 10.1016/j.placenta.2013.08.015 |