Comparison of Transthoracic and Transesophageal 2-Dimensional Speckle Tracking Echocardiography

Two-dimensional (2D) strain imaging has been established as a reliable and reproducible technique for the assessment of left and right ventricular function using transthoracic echocardiography (TTE). However, the reproducibility of transesophageal echocardiographic (TEE) 2D strain imaging and the ag...

Full description

Saved in:
Bibliographic Details
Published inJournal of cardiothoracic and vascular anesthesia Vol. 26; no. 1; pp. 26 - 31
Main Authors Kurt, Mustafa, Tanboga, Ibrahim Halil, Isik, Turgay, Kaya, Ahmet, Ekinci, Mehmet, Bilen, Emine, Can, Mehmet Mustafa, Karakas, Mehmet Fatih, Bayram, Ednan, Aksakal, Enbiya, Sevimli, Serdar
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.02.2012
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Two-dimensional (2D) strain imaging has been established as a reliable and reproducible technique for the assessment of left and right ventricular function using transthoracic echocardiography (TTE). However, the reproducibility of transesophageal echocardiographic (TEE) 2D strain imaging and the agreement with TTE 2D strain imaging remains unclear. In the present study, the authors studied the reproducibility of TEE 2D strain imaging parameters. A comparative, observational clinical study. The echocardiography laboratory of the tertiary referral center. Healthy individuals with a suspected patent foramen ovale. None. Thirty-four patients were included in the study. None of the patients had any structural cardiovascular disease. TTE and TEE images of the subjects were recorded and analyzed offline (EchoPAC 6.1; GE Vingmed Ultrasound AS, Horten, Norway). Longitudinal strain and strain rate measurements of the 4 chambers, the apical long axis, 2 chambers, and the right ventricle were obtained for each record of TTE and TEE. The mean age of the patients in this study was 36 ± 9.2 years. Bland-Altman analysis showed that there were generally good agreements between strain and strain rate measurements on TEE and TTE. The inter- and intraobserver agreement for TEE parameters was good. Transesophageal 2D strain imaging is a reproducible method to measure ventricular function and has a good agreement with TTE 2D strain imaging.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1053-0770
1532-8422
1532-8422
DOI:10.1053/j.jvca.2011.05.014