A novel method for harmonization of PET image spatial resolution without phantoms
Background Estimation of the spatial resolution in real images is extremely important in several fields, including crystallography, optics, microscopy, and tomography. In human PET imaging, estimating spatial resolution typically involves the acquisition of images from a physical phantom, typically...
Saved in:
Published in | EJNMMI physics Vol. 12; no. 1; pp. 23 - 17 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
Cham
Springer International Publishing
14.03.2025
Springer Nature B.V SpringerOpen |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Background
Estimation of the spatial resolution in real images is extremely important in several fields, including crystallography, optics, microscopy, and tomography. In human PET imaging, estimating spatial resolution typically involves the acquisition of images from a physical phantom, typically a Hoffman phantom, which poses a logistical burden, especially in large multi-center studies. Indeed, phantom images may not always be readily available, and this method requires constant monitoring of scanner updates or replacements, scanning protocol changes, and image reconstruction guidelines to establish a equivalence with scans acquired from human subjects.
Methods
We propose a new computational approach that allows estimation of spatial resolution directly from human subject PET images. The proposed technique is based on the generalization of the logarithmic intensity plots in the 2D Fourier domain to the 3D case. The spatial resolution of the image is obtained through the estimated coefficients of a multiple linear regression problem having the logarithm of the squared norm of the Fourier transform as dependent variable and the squared 3D frequencies as multiple predictors.
Results
The proposed approach was applied to a cohort of subjects consisting of [18F]florbetapir amyloid PET images and matching phantoms from a Phase II clinical trial, and a second cohort including β-amyloid, FDG, and tau PET images from the Alzheimer’s Disease Neuroimaging Initiative (ADNI) study. The resulting in-plane and axial resolution estimators varied between 3.5 mm and 8.5 mm for both PET and matching phantom images. They also yielded less than one voxel size across-subjects variability in groups of images sharing the same PET scanner model and reconstruction parameters. For human PET images, we also proved that the spatial resolution estimators showed: (1) a very high reproducibility, as measured by intraclass correlation coefficients (ICC > 0.985), (2) a strong cross-tracer linear correlations, and (3) a high within-subject longitudinal consistency, as measured by the maximum difference value between pairs of visits from the same subject.
Conclusions
Our novel approach does not only eliminate the need for surrogate phantom data, but also provides a general framework that can be applied to a wide range of tracers and other imaging modalities, such as SPECT.
Clinical trial data
Cognito Therapeutics’ OVERTURE clinical trial (NCT03556280, 2021-08-24),
https://clinicaltrials.gov/study/NCT03556280
. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
ISSN: | 2197-7364 2197-7364 |
DOI: | 10.1186/s40658-025-00740-9 |