Gas holdup in slurry bubble columns: Effect of column diameter and slurry concentrations

To study the influence of particle concentration on the hydrodynamics of bubble‐column slurry reactors operating in the heterogeneous flow regime, experiments were carried out in 0.10, 0.19, and 0.38‐m‐dia. columns using paraffinic oil as the liquid phase and slurry concentrations of up to 36 vol. %...

Full description

Saved in:
Bibliographic Details
Published inAIChE journal Vol. 43; no. 2; pp. 311 - 316
Main Authors Krishna, Rajamani, De Swart, Jeroen W. A., Ellenberger, Jürg, Martina, Gilbert B., Maretto, Cristina
Format Journal Article
LanguageEnglish
Published New York American Institute of Chemical Engineers 01.02.1997
Wiley Subscription Services
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To study the influence of particle concentration on the hydrodynamics of bubble‐column slurry reactors operating in the heterogeneous flow regime, experiments were carried out in 0.10, 0.19, and 0.38‐m‐dia. columns using paraffinic oil as the liquid phase and slurry concentrations of up to 36 vol. %. To interpret experimental results a generalization of the “two‐phase” model for gas–solid fluid beds was used to describe bubble hydrodynamics. The two phase identified are: a dilute phase consisting of fast‐rising large bubbles that traverse the column virtually in plug flow and a dense phase that is identified with the liquid phase along with solid particles and entrained small bubbles. The dense phase suffers backmixing considerably. Dynamic gas disengagement was experimented in the heterogeneous flow regime to determine the gas voidage in dilute and dense phases. Experimental data show that increasing the solid concentration decreases the total gas holdup significantly, but the influence on the dilute‐phase gas holdup is small. The dense‐phase gas voidage significantly decreases gas holdup due to enhanced coalescene of small bubbles resulting from introduction of particles. The dense‐phase gas voidage is practically independent of the column diameter. The dilute‐phase gas holdup, on the other hand, decreases with increasing column diameter, and this dependence could be described adequately with a slight modification of the correlation of Krishna and Ellenberger developed for gas–liquid systems.
Bibliography:ark:/67375/WNG-6C6K586R-5
istex:D4DA74990F3761D9E0825EB720E54C58C8D75885
ArticleID:AIC690430204
ISSN:0001-1541
1547-5905
DOI:10.1002/aic.690430204