Predicting cardiotoxicity propensity of the novel iodinated contrast medium GE-145: Ventricular fibrillation during left coronary arteriography in pigs

Severe side effects caused by iodinated radiographic contrast media (CM) are rare, but can occur in high risk patients and during percutaneous coronary intervention. To minimize this risk a new nonionic CM with low inherent osmolality has been designed, giving room for a relatively high concentratio...

Full description

Saved in:
Bibliographic Details
Published inActa radiologica (1987) Vol. 51; no. 9; p. 1007
Main Authors Chai, Chun-Ming, Rasmussen, Henrik, Eriksen, Morten, Hvoslef, Anne-Marie, Evans, Paul, Newton, Ben B, Videm, Signe
Format Journal Article
LanguageEnglish
Published England 01.11.2010
Subjects
Online AccessGet more information

Cover

Loading…
More Information
Summary:Severe side effects caused by iodinated radiographic contrast media (CM) are rare, but can occur in high risk patients and during percutaneous coronary intervention. To minimize this risk a new nonionic CM with low inherent osmolality has been designed, giving room for a relatively high concentration of favorable electrolytes in the isotonic formulation. To test a new radiographic CM (GE-145) in a pig model of cardiotoxicity by comparing its ventricular fibrillation (VF) propensity and hemodynamic effects to that of iodixanol. Test agents were injected into the left anterior descending coronary artery (LAD) of pigs through an inflated balloon catheter (injection volume 25 ml, injection rate 0.4 ml/s, maximum injection time 62.5 s). Series 1: GE-145 (338 mg I/ml) + 45 mM NaCl and iodixanol (321 mg I/ml) + 19 mM NaCl were injected in five pigs. Series 2: GE-145 (320 mg I/ml) + 45 mM NaCl + 0.1, 0.3, or 0.7 mM CaCl₂ and iodixanol (320 mg I/ml) + 19 mM NaCl + 0.3 mM CaC₂ (Visipaque) were injected in six pigs. Iodixanol + NaCl caused VF in 6 of 13 injections (46%) after 60.3±7.5 s (mean ± SD). GE-145 + NaCl did not cause any VF in 13 injections (0%) (P<0.05). Iodixanol + 19 mM NaCl + 0.3 mM CaCl₂ caused VF in 9 of 9 injections (100%) after 61±4 s. GE-145 + 45 mM NaCl + 0.1, 0.3, or 0.7 mM CaCl₂ did not cause any VF during or after 9 injections of each agent (0%) (P<0.05). The least hemodynamic effects were seen with GE-145 + 45 mM NaCl + 0.7 mM CaCl₂. In this model of direct administration of CM into the LAD of anesthetized pigs, the tested GE-145 formulations had a significantly lower propensity to induce VF than iodixanol with electrolytes. Favorable hemodynamic properties of GE-145 can be achieved by optimizing concentrations of sodium and calcium.
ISSN:1600-0455
DOI:10.3109/02841851.2010.504743