Damping factor for monitoring the bone interface at dental implants

Objectives: The aim of this study is to investigate whether the damping of osseointegrated implants, as measured quantitatively with the Osstell™ equipment, is related to the fractal dimension of peri‐implant bone. Material and methods: Fifty‐five maxillary implants in function for 3 years before th...

Full description

Saved in:
Bibliographic Details
Published inClinical oral implants research Vol. 18; no. 6; pp. 738 - 742
Main Authors Veltri, Mario, Balleri, Piero, Ferrari, Marco
Format Journal Article
LanguageEnglish
Published Oxford, UK Blackwell Publishing Ltd 01.12.2007
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objectives: The aim of this study is to investigate whether the damping of osseointegrated implants, as measured quantitatively with the Osstell™ equipment, is related to the fractal dimension of peri‐implant bone. Material and methods: Fifty‐five maxillary implants in function for 3 years before the present study were investigated. Two Osstell™ measurements were obtained for each implant with the transducer oriented first palatally and then distally. Using the half‐power bandwidth method, the damping was calculated from the frequency/amplitude plot obtained from the Osstell™. Damping data were then related to the fractal dimension of peri‐implant bone. Fractal dimensions were calculated using a box‐counting algorithm on digitally processed intra‐oral radiographs of the implants. A Spearman's test was used to verify the correlation between damping and fractal dimension values. Results: All the implants were clinically stable and free from symptoms. The mean ISQ was 63 for the palatal orientation and 71 for the distal orientation. The mean fractal dimension was 1.47; the mean damping value for palatal orientation was 12.3%, while that for the distal orientation was 8.2%. No significant correlation was found. Conclusions: Damping values, measured at peri‐implant bone, were found not to be related to a radiographic parameter of trabecular bone pattern like the fractal dimension. The clinical implication would be that Osstell™ graphs displaying distinct or more rounded peaks might both indicate a stable implant as long as the associated implant stability quotients are in the range of satisfactory values proposed in the literature.
Bibliography:istex:610252ACE7AFBE62085FD111206D3EA4DA161670
ArticleID:CLR1412
ark:/67375/WNG-2VPTV8JM-M
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0905-7161
1600-0501
DOI:10.1111/j.1600-0501.2007.01412.x