Bedside analysis of human milk for adjustable nutrition strategy

Aim: Mother's milk is optimum for preterm infants, but human milk fortifier is required at times, because some nutrients are sometimes insufficient for infant growth. It is important to measure the nutrients in breast milk at bedside so that the amount of nutrients that need to be supplemented...

Full description

Saved in:
Bibliographic Details
Published inActa Paediatrica Vol. 98; no. 2; pp. 380 - 384
Main Authors Menjo, Aiko, Mizuno, Katsumi, Murase, Masahiko, Nishida, Yoshiko, Taki, Motohiro, Itabashi, Kazuo, Shimono, Tomohiro, Namba, Kazuyoshi
Format Journal Article
LanguageEnglish
Published Oxford, UK Blackwell Publishing Ltd 01.02.2009
Blackwell
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Aim: Mother's milk is optimum for preterm infants, but human milk fortifier is required at times, because some nutrients are sometimes insufficient for infant growth. It is important to measure the nutrients in breast milk at bedside so that the amount of nutrients that need to be supplemented can be determined. A human milk analyser (HMA, Miris®) is currently available. We examined if the macronutrient values measured by human milk analyser are comparable with those measured by conventional methods. We also sought to discover whether we could dilute the milk sample used for the human milk analyser measurement if the amount of milk available for testing was insufficient. Subjects and Methods: First, the results of protein, fat and lactose content in breast milk samples obtained using the human milk analyser and conventional methods were compared. Second, we measured diluted samples and compared the values with nondiluted samples. Results: When comparing the human milk analyser and conventional methods, all three nutrients exhibited a significantly positive correlation (p < 0.001); lactose content was reliable on the condition that it is 6–7 g/dL. The lactose content measured by the HPLC method was obtained by 3.05 × human milk analyser value − 13.4. When comparing diluted and nondiluted samples, fat and protein had expected values after dilution whereas lactose did not. Conclusion: The human milk analyser can inform us about the amount of major nutrients in breast milk: fat, protein and lactose. However, when human milk is diluted, the lactose content measured by the human milk analyser is overestimated.
Bibliography:istex:92BAB6C899725C7F28FBD44DDFB750F1EC19AA3E
ArticleID:APA1042
ark:/67375/WNG-2P1557SH-X
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:0803-5253
1651-2227
1651-2227
DOI:10.1111/j.1651-2227.2008.01042.x