Use of Cutometer area parameters in evaluating age-related changes in the skin elasticity of the cheek

Background/aim The decrease of skin elasticity on the cheek is a major concern to woman. The Cutometer® has been widely used to evaluate skin elasticity and its change with aging. Cutometer parameters derived from one suction have been traditionally used to evaluate skin elasticity, and few reports...

Full description

Saved in:
Bibliographic Details
Published inSkin research and technology Vol. 19; no. 1; pp. e238 - e242
Main Authors Ohshima, Hiroshi, Kinoshita, Shigemi, Oyobikawa, Midori, Futagawa, Mikayo, Takiwaki, Hirotsugu, Ishiko, Akira, Kanto, Hiromi
Format Journal Article
LanguageEnglish
Published England Blackwell Publishing Ltd 01.02.2013
John Wiley & Sons, Inc
Subjects
Online AccessGet full text
ISSN0909-752X
1600-0846
1600-0846
DOI10.1111/j.1600-0846.2012.00634.x

Cover

More Information
Summary:Background/aim The decrease of skin elasticity on the cheek is a major concern to woman. The Cutometer® has been widely used to evaluate skin elasticity and its change with aging. Cutometer parameters derived from one suction have been traditionally used to evaluate skin elasticity, and few reports describe the use of multiple suctions to obtain parameters to assess the skin elasticity of the cheek. To find the most suitable Cutometer parameter that reflects age‐related changes in the elasticity of cheek skin using multiple suctions. Methods The cheeks of 32 healthy Japanese women (mean age, 42.3 years) were assessed using the Cutometer® MPA580 by measuring the skin mechanical parameters R0–R9, F2 and F3. Parameters F2 and F3 were obtained by the multiple suction method. The relationship between age and these parameters were then examined. Results Significant negative correlations were found between the age of subjects and R2, R3, R7, R8 and F3. Of these, the correlation coefficient was best between age and F3 (r = ‐0.641), followed R8 (r = ‐0.603). Conclusion Although R parameters have been used to evaluate skin elasticity, our study showed that F3 parameters derived from multiple suctions appear to be suitable for evaluating the elasticity of cheek skin, since this parameter is less influenced by environmental factors compared with R parameters.
Bibliography:istex:FAD987A2A426CDEFA627CF575361C2778AB3BAD0
ArticleID:SRT634
ark:/67375/WNG-S55CXF6T-5
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0909-752X
1600-0846
1600-0846
DOI:10.1111/j.1600-0846.2012.00634.x