Late potentials and QT dispersion after high-dose chemotherapy in patients with non-Hodgkin lymphoma
Summary The most common cardiotoxic effects of high‐dose cyclophosphamide (CY) are electrocardiographic changes and transient arrhythmias. Therefore, we prospectively assessed serial electrocardiogram (ECG) and signal‐averaged electrocardiogram (SAECG) recordings in 30 adult patients with non‐Hodgki...
Saved in:
Published in | Clinical physiology and functional imaging Vol. 30; no. 3; pp. 175 - 180 |
---|---|
Main Authors | , , , , , |
Format | Journal Article |
Language | English |
Published |
Oxford, UK
Blackwell Publishing Ltd
01.05.2010
Blackwell |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Summary
The most common cardiotoxic effects of high‐dose cyclophosphamide (CY) are electrocardiographic changes and transient arrhythmias. Therefore, we prospectively assessed serial electrocardiogram (ECG) and signal‐averaged electrocardiogram (SAECG) recordings in 30 adult patients with non‐Hodgkin lymphoma (NHL) receiving high‐dose CY as part of high‐dose chemotherapy (HDT) regimen. All patients were treated with anthracyclines earlier. Heart‐rate‐corrected QT interval and QT dispersion (QTc and QTc dispersion) were measured from ECG. QRS duration and late potentials (LPs) were analysed from SAECG. Both ECG and SAECG were recorded 1 day (d) prior to HDT (d−7) at baseline, and 1 day (d−2), 7 days (d+7), 12 days (+12) and 3 months (m+3) after HDT. Stem cells were infused on day 0 (d0). Cardiac systolic and diastolic function were assessed on (d−7), (d+12) and (m+3) by radionuclide ventriculography. At baseline, four patients presented with LPs. Cardiac systolic function decreased significantly (53 ± 2; 49 ± 2%, P = 0·009 versus baseline), whilst no patient developed acute heart failure. QRS duration prolonged and RMS40 reduced significantly versus baseline (104 ± 3; 107 ± 3 ms, P = 0·003; 41 ± 4; 38 ± 3 μV, P = 0·03), and six patients (21%) presented with LPs after CY treatment. Both QTc interval and QTc dispersion increased versus baseline (402 ± 5; 423 ± 5 ms, P<0·001; 32 ± 2; 44 ± 3 ms, P = 0·012), and six patients (20%) developed abnormal QT dispersion. In conclusion, high‐dose CY causes subclinical and transient electrical instability reflected by occurrence of LPs as well as increased QTc interval and QT dispersion. Thus, longer follow‐up is required to confirm the meaning of these adverse effects on cardiac function and quality of life. |
---|---|
Bibliography: | istex:3AE64442D9FAF4971D0C88EC5675D9E0CBE31810 ArticleID:CPF920 ark:/67375/WNG-WF3RZPMK-6 ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 ObjectType-Article-1 ObjectType-Feature-2 |
ISSN: | 1475-0961 1475-097X |
DOI: | 10.1111/j.1475-097X.2009.00920.x |